SAFETY INFORMATION
Electrical Connection
A 15 Amp, 120 Volt, 60 Hz circuit with a properly grounded outlet is required .
Preferably, the item will be on a dedicated circuit as other appliances on the same
circuit may cause the circuit breaker to trip or the fuse to blow when the heater is
in operation . The unit comes standard with a 6 ft . (1 .8 m) long, three-wire cord,
exiting the right side of the item . Always plug the unit into a wall outlet/receptacle . An
extension cord or re-locatable power tap, (outlet/power strip), should never be used .
Electrical outlet wiring must comply with local building codes and other
applicable regulations to reduce the risk of fire, electrical shock and
injury to persons .
Do not use this item if any part of it has been under water . Immediately
call a qualified service technician to inspect the item and replace any
part of the electrical system which has been under water .
Grounding Instructions
This heater is for use on 120 volts. The cord has a plug as shown at (A) in figure 1.
An adaptor as shown at (C) is available for connecting three-blade grounding-type
plugs to two-slot receptacles . The green grounding lug extending from the adaptor
must be connected to a permanent ground such as a properly grounded outlet box .
The adaptor should not be used if a three-slot grounded receptacle is available