5.1 Connecting the brass adapters (Fig. 4)
Fasten the supplied brass adapter (11) to the
intake connection (2). Also tighten it using
an open-ended wrench of the right size to
prevent any possibility of leaks.
In addition, connect the brass adapter (10) to
the pressure connection (4) and tighten it with
an open-ended wrench of the right size to
prevent any possibility of leaks.
Caution! Connecting the two brass adapters
to the equipment correctly may lead to
reduced output (delivery rate, height and
pressure and suction height).
5.2 Connecting the intake line
Fasten the ¾" (approx. 19 mm) suction hose
(plastic hose with spiral reinforcement) to the
1¼" NPT (female) intake connection of the
equipment either directly or via a threaded
nipple.
The suction hose used should be equipped
with an intake valve. If the intake valve
cannot be used, a non-return valve should be
installed in the intake line.
Position the intake line so that it rises from
the water withdrawal point to the equipment.
Avoid positioning the intake line higher than
the pump, as this would delay the escape of
air bubbles from the intake line and impede
the priming process.
Install the intake and discharge lines in such
a way that they do not exert any mechanical
pressure on the equipment.
The intake valve should be low enough in the
water to ensure that if the water level falls, the
unit will not run dry.
A leaking intake line will draw in air and
therefore not draw in any water.
Prevent the intake of foreign bodies (sand,
etc.). If necessary, install a coarse filter for
this purpose.
5.3 Connecting the discharge line
The discharge line (min. 3/4" (approx.
19 mm)) must be connected to the 1" NPT
(male) discharge line connector of the
equipment either directly or with the aid of a
threaded nipple.
You can also use a ½" (approx. 13 mm)
discharge line if you use the relevant
couplings. The pump rate is reduced when
using the smaller discharge line.
During the priming process, the shut-off
devices present in the discharge line (spray
nozzles, valves, etc.) must be completely
Anl_AQUINNA_USA_SPK7.indb 13
Anl_AQUINNA_USA_SPK7.indb 13
EN
open so that the air in the intake line can
escape freely.
5.4 Fitting the battery (Fig. 2)
Open the battery cover.
Press the side pushlock button of the battery
pack as shown in Fig. 2 and push the battery
pack into the mount provided. When the battery
is positioned as in Fig. 2, make sure that the
pushlock button latches in place! To remove the
battery pack, proceed in reverse order.
Important!
Use only batteries which are charged to the same
level. Never combine full and half-full batteries.
Always charge the two batteries simultaneously.
The equipment's operating time depends on
the battery with the lower charge level. The two
batteries must always be fully charged before use.

6. Operation

6.1 On/Off /Pump setting switch (Fig. 1/Item 5)
Switch position 0: Off
Switch position I: Pump setting 1
Switch position II: Pump setting 2
Important!
Selecting pump setting 2 increases the maximum
delivery pressure, but it reduces the maximum
operating time of the battery as a result.
6.2 Using for the fi rst time
Install the equipment on a solid and level
surface.
Fill the pump housing with water via the
water filler screw (3). Filling the intake line will
accelerate the priming process.
All the shut-off devices in the discharge
line (spray nozzle, valves etc.) must be fully
opened during intake in order to permit all air
to escape from the intake line.
The intake process starts automatically after
you have pressed the On/Off/Pump setting
switch (5). Water can be suctioned in for up to
5 minutes (maximum suction height).
If the pump is removed after use, it is
essential that it is filled with water again the
next time it is connected and started.
Switch the pump off again after use by pressing
the On/Off /Pump setting switch (5) again and
allow the pump to cool down.