Humidification with an air washer takes some time. An air washer works ac-
cording to the evaporation principle. In this process the air only absorbs as
much water as it needs at the current temperature (self-regulating humidifi-
cation). This means that it could take several hours to achieve a measurable
humidification result. If you put the air washer into operation in a very dry
environment, we recommend that you set the appliance to continuous oper-
ation («Air Humidity») and the speed level to 3 or Turbo («Speed») in order to
effectively increase the air humidity level. Here the size of the room and the
ventilation intervals also play a role. (Also see www.stadlerform.ch/faq).
Cleaning
Prior to any maintenance, cleaning and after each use, switch off the appli-
ance and unplug the mains cable (3) from the socket.
Attention: Never submerge the appliance in water (danger of short-circuit).
• For external cleaning, rub with a damp cloth and then dry thoroughly.
• For internal cleaning, remove the water tank (5) and then pull out the
water tray (2) with the evaporator discs (8) (grab underneath the tray).
• Rinse the water tray (2) and the evaporator discs (8) with clean water
once per week, in order to wash out the particles of dirt removed from
the air.
• Clean the water tray (2), evaporator discs (8) and the water tank (5) thor-
oughly every 2 weeks with a soft brush or sponge and warm water. If
there are lime scale deposits in the water tray or water tank, use a des-
caling solution diluted with water (for mixture ratio, see manufacturer's
instructions). Subsequently rinse the tray and tank with tap water thor-
oughly.
• Descale the evaporator discs (8) approx. every 4 weeks, depending on the
water hardness level. To do so, first empty out any water remaining in the
water tray (2). Then fill the water tray with a descaling solution (mixture
ratio of solution/water according to the manufacturer's instructions) up
to 2 cm below the edge of the tray (leave the evaporator discs in the tray).
Now push the water tray back into the appliance (the tank does not have
to be inserted). Activate the buttons with a hand motion over the display.
Press the «Mode» button three times in order to start the cleaning mode.
The «Clean Mode» symbol lights up. Here the evaporator discs rotate but
the fan does not run. Thus no air is blown into the room. After 20 min-
utes in cleaning mode, the appliance stops and the «Clean Mode» display
blinks. The cleaning process may be run several times depending on the
thickness of the limescale deposits (also see Point 7 under «Setting-Up/
Operation»). Once the cleaning process is finished, switch the appliance
off using the On/Off switch (4). Empty the water tray and clean it thor-
oughly with tap water.
Ionic Silver Cube™
The Ionic Silver Cube (16) prevents the growth of germs and bacteria in the
humidifier due to the continuous release of silver ions. The use of the Ionic
Silver Cube leads to a hygienic room climate. The lifetime of the Ionic Silver
Cube is around one year. We therefore recommend that you replace the
Ionic Silver Cube at the beginning of every humidifying season. The Ionic
All manuals and user guides at all-guides.com
Silver Cube starts working as soon as it comes into contact with water, and
also works when the appliance is switched off.
Anticalc cartridge (optional accessory)
The anticalc cartridge (7) decreases the limescale in the water and thus
reduces the decalcification intervals. The cartridge has to be replaced every
one to three months, depending on the water hardness (see table).
With a water hardness above 21 °dH, we recommend the use of the anticalc
cartridge.
Important: Soak the anticalc cartridge in a water bath for 24 hours before
the first use (not in the water tank!). The resin has to absorb water to reach
high performance.
The period of time that the cartridge is effective for depends on the hard-
ness of the water. This can be tested using the testing strips provided (strips
are stuck to the reverse side of these instructions for use).
1. Dip the testing strips into the water for a second.
2. After around one minute, the results can be seen on the testing strips.
Some of the green boxes change colour into pink. The water hardness is
shown by how many boxes turn pink. Example: If three boxes are pink, then
the water hardness is > 14° dH.
Number of
Water
Degree of
pink boxes
hardness
hardness
(°dH)
0/1
Soft
From 4°dH
2
Moderately
From 7°dH
hard
3
Hard
From 14°dH
4
Very hard
From 21°dH
The cartridge is screwed onto the inside of the water tank lid (6). First,
screw the tank lid (6) off of the water tank (5) and then affix the cartridge to
the inside of the tank lid. Dispose of used cartridges in the household waste.
Do not throw away the water tank lid when changing the cartridge!
Repairs/disposal
• Repairs to electrical appliances must only be carried out by a qualified
electrical technician. If improper repairs are carried out, the warranty
lapses and all liability is refused.
• Never operate the appliance if the adaptor or plug is damaged, after it has
malfunctioned, if it has been dropped or has been damaged in any other
way (cracks/breaks in the casing).
• Do not push any object into the appliance.
• If the appliance is beyond repair, make it unusable immediately by cutting
through the cable and hand it in at the collection point provided for the
purpose.
Cartridge will last for
(with 6 liter/day)
Days
Liter
60 days
approx. 360 L
30 days
approx. 180 L
20 days
approx. 120 L
10 days