Specifications
Model
FCC
IC
Connectors
Antenna Impedence
Frequency
Power output for single cell
phone (Uplink) dBm
Power output for single cell
phone (Downlink) dBm
Noise Figure
Isolation
Power Requirements
Each Signal Booster is individually tested and factory set to ensure FCC compliance. The Signal Booster cannot be adjusted without factory reprogramming or disabling the
hardware. The Signal Booster will amplify, but not alter incoming and outgoing signals in order to increase coverage of authorized frequency bands only. If the Signal Booster
is not in use for five minutes, it will reduce gain until a signal is detected. If a detected signal is too high in a frequency band, or if the Signal Booster detects an oscillation, the
Signal Booster will automatically turn the power off on that band. For a detected oscillation the Signal Booster will automatically resume normal operation after a minimum of
1 minute. After 5 (five) such automatic restarts, any problematic bands are permanently shut off until the Signal Booster has been manually restarted by momentarily removing
power from the Signal Booster. Noise power, gain, and linearity are maintained by the Signal Booster's microprocessor.
The term "IC" before the radio certification number only signifies that Industry Canada technical specifications were met. This device complies with Part 15 of FCC rules.
This device contains licence-exempt transmitter(s)/receiver(s that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is
subject to the following two conditions: (1) This device may not cause interference, and (2)) This device must accept any interference, including interference that may cause
undesired operation of the device. Changes or modifications not expressly approved by weBoost could void the authority to operate this equipment.
Drive Reach Cell Signal Booster
698-716 MHz, 728-756 MHz, 777-787 MHz, 824-894 MHz, 1850-1995 MHz, 1710-1755/2110-2155 MHz
700 MHz B12/17
700 MHz B13
25 .4
25 . 6
4 .8
460061
PWO460061
4726A-460061
SMA-Female
50 Ohms
800 MHz B5
25 . 6
4 .8
4 .8
5 dB (nominal)
> 90 dB
12V, 1 .8A
1700 MHz B4
1900 MHz B2
26 . 7
26 .9
4 . 6
4 .5
ENGLISH