Page 10
•
Digital input — An alarm input for connecting devices that can toggle between an open and
closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a
signal is received the state changes and the input becomes active (shown under System
Options > Port & Devices > Port Status).
Function
Pin
GND
1
3.3 V DC
2
Power
Configurable
3-6 Digital input – Connect to GND to activate, or leave floating
(Input or
Output)
3.3 V max 250 mA
Notes
Ground
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
(unconnected) to deactivate.
Digital output – Internal connection to ground when
activated, floating (unconnected) when deactivated. If used
with an external relay, a diode must be connected in parallel
with the load, for protection against voltage transients.
AXIS P5544 Installation Guide
1
2
A
B
Specifications
Max. load = 250 mA
0 to +40 V DC
Max load = 100 mA
Max voltage = +40 V DC