Belt Or Rotating Brushroll Removal And Replacement; To Remove Belt - Kenmore 592.30413 Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BELT OR ROTATING BRUSHROLL REMOVAL AND REPLACEMENT

WARNING
Electrical Shock and Personal Injury
Hazard.
Disconnect electrical supply before
servicing or cleaning the unit.
Failure to do so could result in
electrical shock or personal injury from
vacuum cleaner suddenly starting.

TO REMOVE BELT

Nozzle Guard
Lay cleaner flat and flip cleaner to expose
nozzle base. Base should lay flat and
face up. To remove nozzle guard, remove
6 screws.
Rotate/pivot the Nozzle Guard and pull
off
Air Passageway
Lift and remove Rotating Brushroll.
Dispose of old belt.
DJ68-00514A-00.indd
15
All manuals and user guides at all-guides.com
TO REPLACE BELT OR
ROTATING BRUSHROLL
Slide belt onto motor shaft.
Place new belt in area of Rotating
Brushroll without bristles.
With new belt in place, pull and slide
Rotating Brushroll into nozzle making
sure that the Rotating Brushroll end caps
are in the correct orientation. Rotate
Rotating Brushroll manually to make sure
belt is properly aligned.
Reposition Nozzle Guard and 6 screws.
Tighten screw securely.
Rotating Brushroll
15
Motor Shaft
Drive Belt
2009.8.22
9:19:51 AM

Publicité

Chapitres

Table des Matières
loading