Insert
Spring
Screw Cap
1. Remove the screw cap,
take out spring and insert.
NOTICE
If it is necessary to cut a hole in the frame, mounting tabs
may be required to strengthen the installation. Mounting
tabs not provided with fire-rated models.
2. Reverse the insert.
11/16"
(17mm)
Optional Lip Extension
Brackets (sold separately)
CSLE-2
3. Replace the insert, spring
and screw cap.
Connect to the power and test the electric
strike before finally mounting the unit.
Please ensure that there is no back pressure on the keeper from the latch.
As with most strikes, this may cause the strike to bind and malfunction. It could
also cause undue pressure on the solenoid and eventual failure of the strike.
CSLE-1
NOTICE
Factory default setting is Fail-Secure.
CAUTION