Problem
No water outlet
Reduced flow rate
Wrong supply of mixed water
Water flows constantly
Obtain the correct inlet pressures and adjust them to 3 bar.
The taps must be installed by qualified technician.
Mandatory installation of the filter seals
Troubleshooting
Cause
Stop valves are closed
Filters are clogged
Battery low/used (version Touch)
Mixer blocked in anti-scald security – cold water failure
Filters are clogged
Stop valves are not opened enough
Cartridge has been improperly configured
Cartouche is obstructed or dirty
The pressions of hot and cold water are unbalanced
The temperature difference between cold and hot water
is too low
Stop valves are not opened enough
Connection warm and cold water inverted
Cartridge is obstructed or dirty
Cartridge out of order
Important informations
Solution
Open the stop valves
Clean or replace
Replace the battery
Check pressure presence
Clean or replace
Open the stop valves
Adjust the cartridge (see page ......)
Clean or replace
Find the good pressure balance;
ΔP < 1bar
Check the water inlets
Open the stop valves
Check the connections
Clean or replace
Replace
15