6.7 Attaching the optional connecting cable for TVIP9X300 and TVIP9X700
Using the optional connecting cables TVAC40700, TVAC40710, TVAC40720 and TVAC40730,
suitable dome cameras can gain the following additional interfaces:
TVAC40700
Suitable for
TVIP91300
Audio input,
3.5 mm stereo
plug
Audio output,
3.5 mm stereo
plug
1 x switching
input
1 x switching
output
Video output,
BNC 1 Vss
6.8

Switching input and switching output

The maximum load values must be observed, otherwise the camera may be
damaged irreparably.
Name
Switching input
DI+
DI-
Switching output DO+
DO-
All manuals and user guides at all-guides.com
TVAC40710
TVIP91700
-
-
-
-
-
-
Connection instructions
5 V DC ~ 12 V DC max. 50 mA
Max. 60 V DC/AC, max. 400 mA, Ron=1.4 Ohm (photo
relay)