• If you are going to install it with a double
chimney, the measure from the required
clearance distance above the hob to your
furniture should be in the range of 910-
1138 mm. (Picture 4b)
• If you are going to install it with a single
chimney, the measure from the required
clearance distance above the hob to your
furniture should be 748 mm. (Picture 3a-
4a) For the installation with one chimney,
use the upper chimney which has
ventilation hole.
Assembling the product fixing parts
(Picture 5-6-7)
Your product is described over double
chimney sheet assembly sampling.
• Center your hob and draw a vertical axis
line on the wall.
• Draw a horizontal reference line measuring
650 mm from the top of your hob. (Picture 5)
• Center the template given with the product
on the reference point you have drawn,
paste it on the wall and mark the holes in
the template with a pencil. (Picture 6)
• Mark the holes for the chimney fixing
parts according to the dimensions given in
picture 6 from the top of your furniture or
ceiling.
• Fix the hood fixing part and chimney fixing
parts to the wall as shown in picture 7.
Hanging, aligning and fixing the hood
(Picture 8-9-10-11)
• Hang your hood on the hood fixing part
that you have fixed to the wall. (Picture 8)
• Align your hob in a central position by
sliding the hood left and right on the fixing
parts. (Picture 9)
• Open the glass cover of the hood and
remove the aluminum filter as shown in
picture 10.
• Fix your hood on the hood fixing part as
shown in picture 11 with the glass cover
open.
• Close the hood glass cover by fitting the
aluminum filter into its place.
• Fitting the chimney outlet pipe
(Picture 12)
• As shown in the picture 12, place the
cover that prevents reversed air flow to the
chimney outlet.
• If your chimney connection pipe's diameter
is 150 mm place the chimney outlet pipe
onto the cover
10
• If your chimney connection pipe's diameter
is 120 mm; Place the chimney outlet pipe
after placing the connection adapter on the
cover.
• Properly insulate the connection points.
Fixing the chimney sheets (Picture
13-14)
• If your chimney connection pipe's diameter
is 120 mm; Stick the supplied tape around
the junction of the connection adapter and
the air outlet slot. (Picture 13)
• Fix the upper chimney sheet to the upper
chimney fixing part with 2 screws from the
sides of the curves. (Picture 13)
• Fix the lower chimney sheet to the lower
chimney fixing part with 2 screws from the
curves on the sides. (Picture 14)
• Complete the installation by fixing the lower
chimney sheet with 2 screws from the
bottom hole circles on the hood. (Picture
14)
Carbon filter installation (Picture 15)
• In the carbon filter installation, the air
sucked from the environment passes
through the aluminium filter and is purified
from odours. After passing through the
carbon filters and the air diverter, it is
supplied back to the environment through
the ventilation grilles on the side surface of
the flue. Flue outlet pipes are not used in
carbon filter installation.
• To install carbon filters, after opening the
glass cover of the hood and removing the
aluminium filter, place the lug sockets on
the carbon filters into the lugs on the motor
carrier as shown in picture 15 and turn
them clockwise to snap them into place.
• Install the aluminium filter and fix the flue
plates as shown in Picture 14.
If the oil filters are not cleaned and maintained
regularly and the carbon filter is not replaced
when its life is over (approximately 4 months),
there is a possibility of fire.
Final check
• Control your hood and lamp by operating it
as described in the user manual.