17. For Honda engines route throttle cable through
throttle bracket as shown in Figure 14. The cable end
shoulder should be positioned as shown against the
end of the throttle bracket. Tighten down throttle
bracket making sure not to overtighten.
1
2
Honda Engine Shown
1. Throttle Cable
2. Throttle Bracket
3. Cable Stop
4. Throttle Stop Screw
18. Move throttle control on control panel to low idle
speed
position while inserting cable end through
cable stop.
19. Rotate engine throttle to high idle speed position.
Move throttle control to high idle speed.
Tighten cable screw to secure cable.
DO NOT overtighten cable stop.
20. Pull throttle control on panel back to low idle, then
push back to high dile.
21. If the engine throttle lever is not contacting the end of
the throttle stop screw, the cable stop must be
loosened and the throttle cable wire pulled through the
cable stop further.
22. Reinstall throttle cover. Secure with two original
10mm screws.
23. Use wire ties to secure convoluted tubing to handle-
bar support. See Figure 15.
8
All manuals and user guides at all-guides.com
3
FIGURE 14
1
FIGURE 15
1. Wire Ties
24. Clutch control lever should line up with console corner.
Adjust brake band by turning the adjusting
screw at bottom of brake band with an allen wrench.
Adjustment should be snug enough but not too tight
to cause smoking of the drive belt. Install the locking
nut to hold the brake band adjustment in place.
25. If brake band cannot be adjusted, reposition engine.
Slots on engine plate should be showing 7/32" to
1/4". See Figure 16.
4
26. Install one (1) 1/2–13 flangelock nut (flange side
towards the outside of the unit) onto the guard sup-
port rod before guard is reinstalled.
27. Reinstall guard onto side of unit using original hard-
ware. Secure "L" bracket to guard using new hard-
ware.
All vehicles operated outside the U.K. in the Euro-
pean community do not apply an operator instruction
decal.
28. In North America and the United Kingdom apply the
operator instruction decal. See following illustration.
29. Insert the two (2) 15 1/2" (394 mm) cable ties through
the holes in the literature mounting plate (See Fig.
17). Secure literature tube using the cable ties.
5165
FIGURE 16
NOTICE