3. Functions indicator
3.1. Graduation
The graduation of the indicator depends on the weighed load:
from 40 to 2000 kg the weight is shown in 2 kg steps, or
from 20 to 2000 kg the weight is shown in 1 kg steps
3.2. Before weighing: check zero point
Before each weighing it is necessary to check whether the system is unloaded and free. The
indicator is fitted with an automatic zero correction. This means that small deviations of the zero
point will be corrected automatically. If the indicator does not determine the zero point
automatically, it must be done manually using the
3.3. Gross weighing
After lifting a load, the display shows the gross value of the weighed load.
3.4. Net weighing: automatic tare
The indicator offers the possibility to reset tare weights to zero automatically. This way added or
subtracted weights can be determined. After taring, the display continues in the smallest step.
Lift load.
Press key
0/T
.
The indicator is set to zero.
The "NET" pointer shows that a tare weight is activated.
Place or remove the net load.
The display shows the net value of the weighed load.
When removing load, this is a negative value.
By executing a zero setting in unloaded position, the system will return to the standard
weighing mode.
3.5. Net weighing: manual tare entry
0/T
key.
‐ 9 ‐