Device-Status 17) - Vega VEGAPULS C 21 Mise En Service

Capteur radar pour mesure de niveau continue
Masquer les pouces Voir aussi pour VEGAPULS C 21:
Table des Matières

Publicité

Write access protection parameterization lock
Command
Response
aXWAPPL!
a<value><CR><LF>
Example:
Command
Response
aXWAPPL!
0+000<CR><LF>
Write access protection unlock with emergency code
Command
Response
aXWAPEC <va-
a<value1><CR><LF>
lue1>!
Example:
Command
Response
0XWAPEC
0+000<CR><LF>
+0123456789!
13.5 Device-Status
Failure
Code
F013
F017
F025
F036
F040
F080
F105
F260
F261
F264
F265
Value 4 with aD0!, aR0!, aRC0!, value 2 with aD0! behind aV!
17)
VEGAPULS C 21 • SDI-12
17)
DesCRiption
No measured value available
Adjusted span too small
Error in the linearization table
No executable software
Error in the electronics
General software error
Measured value is determined
Error in the calibration
Error in the device setting
Installation/setup error
Measurement function
Description
a: sensor address
<value>: VVO-Status +eee
<CR><LF>
Description
Description
a: sensor address
<value1>: 10 numbers (device emergency unlock code)
<CR><LF>
<value1>: VVO-Status