Getting Started - Ribimex RIBITECH PRCOMP1/KIT Manuel D'instructions Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Prolonged used of a tool (or other machines) may expose the operator to vibrations that may product white
finger disease (Raynaud's syndrome) or carpal tunnel syndrome.
These conditions reduce the hand's ability to feel and regulate temperature, produce numbness and may
cause nerve and circulation damage and tissue necrosis.
All factors that contribute to the white finger disease are not known.
Some of the factors mentioned in the development of the white finger disease are: cold weather, smoking
and diseases or physical conditions that affect blood vessels and blood transportation, as well as, high
vibration levels and long periods of exposure to vibration.
To help in the prevention and reducing the risk of the white finger disease, please note the following:
-- wear gloves and keep your hands warm;
-- maintain a firm grip at all times, but do not squeeze the handles with constant pressure,
-- take frequent pauses
The operator should closely monitor the condition of their hands and fingers, and if any of the symptoms
appear, seek medical advice immediately.
c- Electromagnetic field
Warning! This machine produces an electromagnetic field during operation. This field may under some
circumstances interfere with active or passive medical implants. To reduce the risk of serious or fatal injury,
we recommend persons with medical implants to consult their physician and the medical implant manufacturer
before operating this machine
3.6- Warning!
- Do not assume your knowledge of the compressor. Remember that a split second of negligence is sufficient
to cause serious damage and/or injury.
IV. GETTING STARTED
Before any intervention on product, ensure that product is disconnected from its power source.
4.1- Unpacking
Remove product from its packaging.
Check that tool and accessories are not damage.
4.2- Preparation
Place machine on a flat, stable and solid surface.
Use compressor laying flat.
Ensure the compressor is switched off (with switch on the (0) position).
4.3- To connect the air gun to the hose coupler
Remove the air hose (5) from its compartment (2).
Insert the nipple of the air gun (8) into the hose quick coupler (7).
Ensure that the air gun nipple is securely locked inside the quick coupler.
4.4- To disconnect the air gun from the hose coupler
Release the air from the system by pressing the air release valve (12).
WARNING: If the system is still under pressure, disconnecting the gun may cause uncontrolled hose
movement that could injure you or cause damage.
Pull down the ring of the quick coupler (7); hold the gun (8) firmly to prevent rapid ejection; then gently pull
the male connector of the gun (8) out of the quick coupler (7).
4.5- To connect and disconnect accessories to/from the air gun
The flexible hose (9) and the blowing nozzle [a] can be mounted on the gun threaded nozzle by screwing.
Use a wrench to screw or unscrew the threaded end of the hose (9) or the threaded end of the blowing nozzle
[a] onto the tip of the gun.
Page 16 / 31

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

518106

Table des Matières