PRE-INSTALLATION
Air Discharge Requirements
HORIZONTAL BOTTOM
EXIT INTO HARD
FLOOR DUCT
DFL40
4" x 10" Bottom exit
PLUS 1- 4" flex duct
DISCHARGE
(for hard ducting
REQ.
under 2 .5" deep) .
Duct 6 or 7 is recommended .
DFL35
4" x 10" Bottom exit PLUS 1-
4" flex duct
DISCHARGE
(for hard ducting
REQ.
under 2 .5" deep) .
Duct 6 or 7 is recommended .
HORIZONTAL BOTTOM
EXIT INTO HARD
FLOOR DUCT
DFM35
4" x 10" Bottom exit PLUS
1- 4" flex duct
DISCHARGE
(for hard ducting
REQ.
under 2 .5" deep) .
Duct 6 or 7 is recommended .
DFM30
4" x 10" Bottom exit PLUS 1-
4" flex duct
DISCHARGE
(for hard ducting
REQ.
under 2 .5" deep) .
Duct 6 or 7 is recommended .
DFM25
4" x 10" Bottom exit
DISCHARGE
REQ.
DFM20
4" x 10" Bottom exit
DISCHARGE
REQ.
DFM16
4" x 10" Bottom exit
DISCHARGE
REQ.
VERTICAL
BOTTOM EXIT
INTO HARD
FLOOR DUCT
220
175
5" x 9-3/4" Bottom
exit does not require
additional ducts .
200
175
5" x 9-3/4" Bottom
exit does not require
additional ducts .
VERTICAL
BOTTOM EXIT
INTO HARD
FLOOR DUCT
225
155
5" x 9-3/4" Bottom
exit does not require
additional ducts .
210
150
5" x 9-3/4" Bottom
exit does not require
additional ducts .
175
160
5" x 9-3/4" Bottom
exit does not require
(40 in .
) .
2
additional ducts .
135
5" x 9-3/4" Bottom
exit does not require
(40 in .
) .
2
additional ducts .
135
5" x 9-3/4" Bottom
exit does not require
(40 in .
) .
2
additional ducts .
HORIZONTAL OR
VERTICAL – USE DUCTS
3, 4 & 5 INTO HARD
FLOOR DUCT
Minimum CFM
165
Horizontal or vertical .
Use ducts 3, 4, and 5 .
Minimum CFM
165
Horizontal or vertical .
Use ducts 3, 4, and 5 .
HORIZONTAL OR
VERTICAL – USE DUCTS
3, 4 & 5 INTO HARD
FLOOR DUCT
Minimum CFM
155
Horizontal or vertical .
Use ducts 3, 4, and 5 .
Minimum CFM
155
Horizontal or vertical .
Use ducts 3, 4 and 5 .
Minimum CFM
160
Horizontal or vertical .
Use ducts 3, 4 and 5 .
Minimum CFM
85
115
Horizontal or vertical .
Use any two ducts:
3, 4 or 5 .
Minimum CFM
85
115
Horizontal or vertical
Use any two ducts:
3, 4 or 5 .
11
5" FRONT EXIT
4" FLEX DUCTS
FLEX DUCTS
215
Three ducts
MINIMUM .
N/A
Four ducts
recommended .
215
Three ducts
MINIMUM .
N/A
Four ducts
recommended .
5" FRONT EXIT
4" FLEX DUCTS
FLEX DUCTS
285
Four ducts
N/A
MINIMUM .
220
Three ducts
N/A
MINIMUM .
190
Three ducts
N/A
MINIMUM
.
132
Two ducts
N/A
MINIMUM .
132
Two ducts
N/A
MINIMUM .
N/A
N/A
N/A
N/A
N/A
N/A
N/A