Electrical Connection - SunWare TX Serie Instructions D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
5

Electrical connection

Installing the cable plug and couplers
Each module comes with a cable plug and socket, cover cap and a
10m connection cable for electrical connection (
The connectors are VDE and GL approved for direct current voltage
(DC) up to 50V/16A.
First, place the cover caps onto the cable ends.
Screw the cable plug (male) to the 40cm long connection cable of
the module and the socket to the supply line.
The backs of plug and socket show the earthing symbol
figure 1.
Connect "-", blue (negative) to the terminal with
Connect "+", red (positive) to the terminal with the figure 1 (
To prevent reverse polarity attach the plug and socket element
(
Pic. 4.3)
and check for correct polarity. Are the gland colours for
each contact on either side the same?
The other end of the supply line can now be connected to the charge
controller.
The coupler at the end of the supply line can be sealed with the
cover cap to prevent plug corrosion (
optionally be supplied with an angled housing and flange socket
(
Pic. 4.7 + 4.8
).
IMPORTANT!
When plugging in the couplers make sure that the contacts and O-
ring seals are clean. Thoroughly remove any sand and dirt to ensure
permanent sealing.
Combination with other solar modules:
SunWare solar modules can easily be combined with each other.
Combination with charge controllers:
Add a SunWare FOX solar charge controller to your SunWare solar
module for a complete solar energy system.
All SunWare solar modules do not require a MPPT controller!
15
Pic. 4.1
).
and the
Pic. 4.2
)
Pic. 4.5
). The plug system can
6
Technical structure of the modules
Component
Mounting plate
3mm aluminium sandwich,
powder-coated
Solar cells
crystalline solar cells,
within EVA laminate,
mounting plate fully encased in EVA
Cable outlet
Connection box sealed sea watertight
and screwed to base plate
Connnection cable
PUR sheathed cable
PVC sheathed glands
2 x 1.5mm², red = "+", blue = "-"
6.5mm outer diameter
Frame
high-quality tarpaulin fabric
highly UV resistant (class 7 of 8)
bactericidal
Sewed edge
20mm all round sandwich core
for medium-duty sewing machines
min. stitch length 8mm
needle 140 - 160
Fastening
Tenax / Loxx elements
hole diameter 9.0mm
For technical data of your solar module visit www.sunware.de
Description
EN
16

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tx12039Tx42039Tx42052Tx12052Tx22039Tx22052

Table des Matières