7.3.2 Manager : flow
Function modes
- Smart-grid
Optimized mode for self-consumption and performance.
- Back-Up
Mode optimized for Uninterrupted Power Supply (UPS). Batteries are maintained fully
charged. Discharge of batteries is allowed only in the case of grid outage.
- Off-Grid
Mode optimized for electrification of isolated sites (without grid).
- On-Grid
Inject the totality of the solar production in the « GRID CONNECTION » connector.
Using batteries is not possible with this mode.
For more information concerning the modes of operation and priorities, refer to the «
Integrated function modes » table in the appendix section at the end of the document.
Allow feed-in to the grid:
Allow to block or authorize injection of electricity to the « GRID CONNECTION » connector.
Max feed-in power to the grid :
Set the maximum power to inject to the grid through the « GRID CONNECTION » connector (between
0 and 9000 W)