provided. At the same time open the vent cap (2) to let out the air. This ensures that the mechanical seal is well
lubricated and that the pump immediately starts to work regularly. Dry operation causes irreparable damage
to the mechanical seal.
2.
The filling cap must be screwed on accurately until it stops (1), as must the vent cap (2).
3.
Insert the plug of the power cable in a 230 V power socket. Attention! The pump motor will start immediately,
the water will start to come out after a maximum time of 3 minutes, depending on the depth of the water level, in
the well or cistern.
4.
The pump will continue to work and supply water. Attention! Avoid dry running.
5.
To switch off the pump, take the plug out of the power socket.
9. ELECTRONIC CONTROL INTERFACE
(A)
9.1 Overview of the features
Description
Controller board voltage,
frequency
Power on/off indicator
Motor on/off indicator
Alarms indicator
Pressure indicator
Mode indicator
Auto Mode
Manual Mode
Dry-running protection
Anti-leakage
Max pump on protection
Cut-in pressure
Cut-out pressure
Auto priming
Selection buttons
= Fixed; = Selectable
9.1.1 Description of the display:
(A) Pressure indicator LEDs
10 LEDs are used for indicating pressure from 0 to 6 bar. When the pressure in the system changes, the LEDs light
up and switch off accordingly.
Function
Auto Mode
Parameters
1x230 V, 50/60 Hz
(30 minutes)
Variable (1.5 – 3.0bar)
(Cut-in + 1 bar)
Display configuration
ENGLISH
Set
ON: Enabled
OFF: Disabled
4
(B)
(C)
Alarm Reset
16