8 Putting out of operation

As this is a complete system, the individual components can be switched off only in combination with each
other.
NOTICE
• Observe the operating instructions of the welding components, such as the robot welding power
BAL.0331.0 • 2019-03-11
Pos.
Designation
(4)
Control lead connection intermediate cable assembly
(5)
Compressed air inlet
(3)
Gas input
(9)
Control lead connection welding torch
(2)
Compressed air outlet
(10)
Air-blast trigger: Press trigger for air flow.
(11)
Gas test trigger: Press trigger for gas flow.
(12)
Inching trigger: Allows a manually-controlled wire supply without gas flow.
Press trigger = wire is fed.
(13)
Press (11) + (12) to transport the wire backwards.
, cooling unit
source iROB Pulse
iROB Cool and welding torch.