1.
1 x 6 PLUS-MINUS SKT High-voltage device with ultrasound
EN
2.
6 x PLUS-MINUS SKT stainless steel contact plates
3.
1 x High voltage warning sticker
4.
1 x Bonnet contact switch with stainless steel bracket
5.
2 x Blade receptacles
6.
20 x Cable ties
1.
2.
3.
1x
6x
1x
Technical data
Operating voltage:
Power consumption:
Reverse polarity protection:
Fuse in the fuse holder:
Output voltage:
Function control light for high voltage:
Ultrasound frequency:
Dispersion radius:
Dispersion angle:
Sound pressure:
Function control light for ultrasound:
Moisture protection:
Please note before installing
1.
Please prominently attach the included yellow warning sticker (3) in the engine compartment
(e.g. on the air filter housing).
2.
The unit is largely maintenance-free. Prolonged use may lead to contamination of the stainless steel contact
plates, which can cause the high voltage to break down (function control LED shuts off).
Corrective
measure: Switch off the device, wait approx. 3–5 minutes, then clean/reattach the stainless steel
contact plates (cable ties). Carefully check that the stainless steel contact plates (2) are correctly installed in
order to avoid a short circuit, for example due to current leakage or the plus stainless steel contact plate
(marked with a yellow sticker) coming into contact with an earthed part.
3.
It takes several seconds for the voltage to build up after the device is switched on. Once sufficient voltage is
available, the yellow function control LEDs will begin to blink.
4.
Never clean the unit using a high-pressure hose or steam blower!
Caution overvoltage protection!
When jump-starting, welding or quick-charging, please switch off the device!
8
4.
5.
6.
1x
2x
20x
12 V
approx. 17 mA (including after a short circuit)
is provided
0.5 A F
approx. 300 V
two LEDs that blink at irregular intervals,
also functions as a deterrent.
20–25 KHz, frequency modulation
360°
160°
approx. 100 dB
small LED
shock and splashproof
Prior to
Function
Trouble
Installation
installation
check
shooting
Martens mark their territory with scent marks. Before fitting the device, the area to be protected – i.e. the engine com-
partment, underbody and wheel housing – must be thoroughly cleaned. We recommend using our STOP&GO odour
remover (item code
07503). It is also advisable to neutralise the parking area by cleaning it.
All units are checked prior to being dispatched. Please check again before
and negative battery cables directly to the car battery. When the device is operated for the first time, the red function
control diode should begin to blink or remain on within no more than 3 minutes. Once the device has been switched
off, the stainless steel contact plates will retain a high-voltage charge for up to 5 minutes, which means that you should
not touch them. Alternatively, you can intentionally discharge the plates, for example using an insulated screwdriver.
If the function check is successful but voltage fails to build up after installation, an installation error has occurred (see
trouble shooting).
How the device works
This device works according to the electric fence principle to repel martens from the engine compartment. Six double
stainless steel contact plates featuring insulation-displacement contact technology (SKT) are installed in the engine com-
partment and provide a safe but effective electric shock when touched. The panic protection control gives the animal
enough time to flee before the capacitor is recharged, thereby avoiding any serious harm to the marten due to perma-
nent electric shocks. Ultrasonic waves in the frequency range of animal fear and warning cries signal extreme danger to
the marten. The device features frequency modulation in order to prevent habituation.
Also protects your engine compartment from rodents and
Prior to
Function
Trouble
Installation
installation
check
shooting
Please remove the fuse from the holder during installation. Install the
partment so that the area of diffusion of the ultrasonic speaker is as large as possible and the device is protected from
excessive heat, water and dirt. We recommend positioning the device so that the area of diffusion is directed downwards
from above. For clarification: Imagine the area of diffusion is the beam of a torch, which needs to illuminate the largest
area possible. We recommend using the optional mounting bracket (item code 07599).
The positive battery cable with a fuse holder is connected via the bonnet contact
or directly to a 12 V plus connection (after or at the vehicle's fuse box). Connect the earth cable (–) to an original earthing
point on the vehicle body. The control line (green cable) must be connected to the plus ignition power supply of the
15). This terminal is located on the ignition switch or on the car radio's Europlug. If the
on-board power supply (terminal
cable (terminal 15) is properly connected, the device will switch on automatically as soon as the ignition is switched off.
Note: If you do not connect the cable (terminal 15), the device will remain permanently switched on. This does not affect
the operation of the device, but it is not recommended.
Lay the flat, two-core high-voltage
cable so that it remains unaffected by other components and functions in the engine
compartment. In particular, avoid sources of intense heat such as exhaust systems etc. Slide the base with the stainless
steel contact plates (2) successively along the high-voltage cable to the desired positions in the upper third of the engine
compartment. Secure the contact plates to the cable core by pressing the plates together with the black base. If you hear
a click, this means that a connection has been established between the contact plate/insulation displacement connector
and the high-voltage cable. Then use cable ties to secure the contact plates (using the fastening eyes/tunnel on the
base) and the high-voltage cable within the vehicle. Ensure a safety clearance of at least 10 mm from other live parts. For
non-standard sized vehicles, such as SUVs, mobile homes and vans, we recommend that the six included stainless steel
contact plates be supplemented with additional contact plates as needed (expansion set item code 07557).
Please
note that once they have been secured to the cable, the stainless steel contact plates should not be removed and
repositioned elsewhere on the cable as this interrupts the flow of electricity.
We recommend installing the device, including the stainless steel contact plates, in the upper third of the engine com-
partment since martens, due to their burrowing behaviour, instinctively make their way up through the engine cavity.
Moreover, this facilitates installation and ensures that all of the components are better protected from dirt. Caution: The
plus stainless steel contact
plate (marked with a yellow sticker) must not touch any earthed parts.
Circuit
Warranty
diagram
installing. To do this, connect the positive
raccoons.
Circuit
Warranty
diagram
device in the upper third of the engine com-
switch to the unswitched terminal 30