TEMPERATURE CONTROL
You have two heating temperatures at your disposal. These can be
controlled between +6 °C and + 30 °C
Comfort temperature
:
This is the temperature you wish to have during your hours of pre-
sence.
You control the required comfort temperature with the button
8
(the marking corresponds to around 20 °C).
Reduced temperature
This is the economy temperature ensured during periods when
you are absent or during the night.
You control the required reduced temperature with the button
6
(the marking corresponds to around 15 °C).
We advise you to set the reduced temperature to a value 4 to 5 °C
less than the comfort temperature.
MODE SELECTION
Reduced
Auto
The selector
7
allows you to choose the mode of operation:
This mode maintains the comfort and reduced
Automatic
temperatures according to the time ranges
mode:
programmed on the timer.
This mode permanently maintains the comfort
Permanent
temperature set with the button
comfort mode:
This mode permanently maintains the reduced
Perm. reduced
temperature set with the button
mode:
This mode permanently maintains a minimum
Frost protection
temperature (6 °C) during prolonged periods of
mode:
absence, protecting your dwelling against frost
hazards. This temperature cannot be varied.
TIMER PROGRAMMING
The quartz timer of your THERMOFLASH TS allows you to program the
time ranges corresponding to your comfort and reduced tempera-
ture settings. Your THERMOFLASH TS has been programmed at the
factory as follows:
ALL
7
DAYS
6h00
If these programmed settings meet your requirements, there is no
need to make any changes. If you wish to modify the settings, how-
ever, you must:
- raise the cover
1
- move the segments
2
:
towards the outside for comfort temperature periods (red zone
visible)
towards the inside for reduced temperature periods (red zone
concealed).
Programmed settings will be repeated
every day of the week and every week
when the selector
Programming in increments of:
1
- Daily version: 10 minutes
12
- Weekly version: 1 hour.
3
Minimum interval between two periods:
- Daily version: 20 minutes.
- Weekly version: 2 hours.
:
Comfort
Anti-frost
8
6
7
is set to
OK
Example of daily programming:
ALL
7
DAYS
6h00
Example of weekly programming:
MONDAY
TO
FRIDAY
6h00
.
SATURDAY
.
&
SUNDAY
7h00
Note: the heating system will start at the programmed time (e.g.
6 h 00). If you get up at 6 h 00, program the start of the comfort
period at 5 h 00 or 6 h 30, depending on the inertia of your installa-
tion, in order to obtain the comfort temperature at 6 h 00.
TECHNICAL CHARACTERISTICS
- Comfort and reduced temperature range: + 6 °C to + 30 °C
- Frost protection: 6 °C
- Static differential: 0.3 degree
- Power supply: 230 V +10/-15 %
- Power consumption: < 25 mA by 230 V
- Power reserve: 72 hours (after 100 hours power supply)
- Output: 1 potential-free changeover contact
- Switching capacity: 8 A/250 VAC cos
23h00
- Operating temperature: 0 °C to + 50 °C
- Storage temperature: – 10 °C to + 60 °C
- Humidity: max. 90 % at 20 °C
- IP 30
- Screw terminal connection:
Space requirement
8h00
8h00
j = 1
2 A/250 VAC cos j = 0.6
rigid wire up to 2.5 mm
flexible wire up to 1.5 mm
12
9
3
6
16h00
23h00
1
12
9
3
6
18h00
23h00
23h00
2
2