Maintenance; Display Errors - MW TOOLS WD70I Mode D'emploi

Chauffage diesel
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

M1.1.WD70I.NLFREN - 25042019
EN

8 Maintenance

To ensure the best maintenance and/or transportation procedure, please observe the following
procedure:
1. Empty the fuel tank.
2. If remainders are still present, pour in clean fuel and empty it again
3. Close the tank filler plug, dispose of the fuel as per the applicable regulations.
4. To ensure proper generator maintenance, keep it levelled to prevent fuel leaks, keep it in a dry place and protect from
getting damaged.

9 Display errors

See figure 1, No. 2, B
Error code
Possible cause
F0
The ON/OFF switch is turned ON when the
generator is plugged
F1
No fuel
Fuel is contaminated
Photocell is dirty or damaged
Fuel filter is dirty
Ignition error
F2
Interrupted cable
Sensor is damaged
F3
Internal generator overheating
Anti-tilting sensor action
LO
External temperature below -9 °C
CH
Continuous operation (55 °C)
Solution
Operation error
After disconnecting the generator, see that the
switch is in the OFF position, plug the generator in
and turn the switch ON
Photocell error
Turn the switch OFF, refill the fuel tank
Turn the switch on OFF, empty and refill the fuel
tank. Clean the filter using clean fuel, do not
damage the filter (see chapter 7)
Contact the technical service center
See chapter 7
Contact the technical service center
Temperature control sensor error
Contact the technical service center
Contact the technical service center
Thermostat error
Turn the generator OFF, wait until it is cooled down
Replace the heater on a level and stable surface
Normal condition
Normal condition