Supply
Personnel in charge of supply must be fully qualified, must be familiar with the manufacturer's manual as well as the
effective regulations for safe supply of generators.
Only the fuel types specifically listed on the generator's nameplate are to be used.
Before refuelling, shut down the generator and wait for it to cool down.
Fuel cisterns are to be located in separate facility.
All fuel containers are to be located within safe distance from the generator, as per the applicable regulations.
Fuel is to be stored in rooms with insulated floor, so that the fuel cannot penetrate the floor into the open flame below
causing fuel combustion.
Fuel storage need to follow all the applicable regulations.
Safety considerations
The generator should never be used in rooms with fuel, paint thinners and other combustible fumes.
All applicable local rules and regulations need be observed while using the generator.
Generators in operation near tarpaulin, screens or other similar materials need to be located a safe distance away. The use
of inflammable covers is highly encouraged.
The device is to be used in well ventilated interiors only. To ensure proper air circulation, a proper opening is required, as
per the applicable regulations.
For generator power feed observe closely the voltage and frequency values given in the nameplate.
Only use grounded, three-core extension cords.
Minimal safety distance between the generator and combustible materials is: front = 2.5 m; side, up and back = 1.5 m.
To avoid fire, hot or working generator is to be placed on a stable and levelled flooring.
Animals are to be kept at a safe distance away from the generator.
Unplug the generator at all times during downtime.
Thermostat control allows the generator to be turned on at any time.
The generator must not be used in frequently visited rooms and in bedrooms.
Do not obstruct the airflow (back of the device) and air intake (front) of the generator.
If the generator is plugged in, hot, or currently running, it must not be moved, manipulated, refuelled or attempt
maintenance work of any kind.
Do not channel the air flow at intake or the generator output.
Keep the safe distance between the hot parts of the generator and thermos-sensitive or combustible materials(including
feeder cable).
If the supply cord is damaged, it must be replaced by the manufacturer,or similarly qualified persons in order to avoid a
hazard.
Heater is not located immediately below a socket-outlet.
Do not use the heater with a programmer, timer or any other device that switches the heater on automatically.

2 Technical data and description

2.1 Table
Model
Power
Fuel consumption
Kind of fuel
Fuel tank capacity
Electrical supply
Net weight
Nozzle type
WD70I
20 kW
1.9 l/h
Diesel / Kerosene
10.5 liter
220-240 V ~ 50 Hz 110 W
18.2 kg
0.4 GpH 60° S Danfoss