M1.1.WD70I.NLFREN - 25042019
EN
Supply
•
Personnel in charge of supply must be fully qualified, must be familiar with the manufacturer's manual as well as the
effective regulations for safe supply of generators.
•
Only the fuel types specifically listed on the generator's nameplate are to be used.
•
Before refuelling, shut down the generator and wait for it to cool down.
•
Fuel cisterns are to be located in separate facility.
•
All fuel containers are to be located within safe distance from the generator, as per the applicable regulations.
•
Fuel is to be stored in rooms with insulated floor, so that the fuel cannot penetrate the floor into the open flame below
causing fuel combustion.
•
Fuel storage need to follow all the applicable regulations.
Safety considerations
•
The generator should never be used in rooms with fuel, paint thinners and other combustible fumes.
•
All applicable local rules and regulations need be observed while using the generator.
•
Generators in operation near tarpaulin, screens or other similar materials need to be located a safe distance away. The use
of inflammable covers is highly encouraged.
•
The device is to be used in well ventilated interiors only. To ensure proper air circulation, a proper opening is required, as
per the applicable regulations.
•
For generator power feed observe closely the voltage and frequency values given in the nameplate.
•
Only use grounded, three-core extension cords.
•
Minimal safety distance between the generator and combustible materials is: front = 2.5 m; side, up and back = 1.5 m.
•
To avoid fire, hot or working generator is to be placed on a stable and levelled flooring.
•
Animals are to be kept at a safe distance away from the generator.
•
Unplug the generator at all times during downtime.
•
Thermostat control allows the generator to be turned on at any time.
•
The generator must not be used in frequently visited rooms and in bedrooms.
•
Do not obstruct the airflow (back of the device) and air intake (front) of the generator.
•
If the generator is plugged in, hot, or currently running, it must not be moved, manipulated, refuelled or attempt
maintenance work of any kind.
•
Do not channel the air flow at intake or the generator output.
•
Keep the safe distance between the hot parts of the generator and thermos-sensitive or combustible materials(including
feeder cable).
•
If the supply cord is damaged, it must be replaced by the manufacturer,or similarly qualified persons in order to avoid a
hazard.
•
Heater is not located immediately below a socket-outlet.
•
Do not use the heater with a programmer, timer or any other device that switches the heater on automatically.
2 Technical data and description
2.1 Table
Model
Power
Fuel consumption
Kind of fuel
Fuel tank capacity
Electrical supply
Net weight
Nozzle type
WD70I
20 kW
1.9 l/h
Diesel / Kerosene
10.5 liter
220-240 V ~ 50 Hz 110 W
18.2 kg
0.4 GpH 60° S Danfoss
17