IO-Link Data Dictionary
21.10.01.00097/03
Switch Point 2
Switch Point 2 - Upper Threshold
62
0x003E
1
SP2/FH2
62
0x003E
2
rP2/FL2
Switch Point 2 - Lower Threshold
Switch Point 2 - Logic
63
0x003F
1
Ou2
Switch Point 2 - Mode
63
0x003F
2
Ou2
63
0x003F
3
Hy2
Switch Point 2 - Window Hysteresis
80
0x0050
1
dS2
Switch Point 2 - Switch-on delay
80
0x0050
2
dr2
Switch Point 2 - Switch-off delay
Condition Monitoring [CM]
Permissible Leakage Rate
108
0x006C
0
-L-
Observation
Monitoring
Process Data
40
0x0028
0
Process Data In Copy
64
0x0040
1
Sensor Value
64
0x0040
2
Sensor Value LO
64
0x0040
3
Sensor Value HI
66
0x0042
1
Supply Voltage
66
0x0042
2
Supply Voltage LO
66
0x0042
3
Supply Voltage HI
Communication Mode
564
0x0234
0
Communication Mode
Counters
Counter cc1
140
0x008C
0
cc1
Counter cc2
141
0x008D
0
cc2
Counter ct1
143
0x008F
0
ct1
Counter ct2
144
0x0090
0
ct2
Diagnosis
Device Status
32
0x0020
0
Error Count
36
0x0024
0
IO-Link Device Status
Detailed Device Status
37
0x0025
1-15
Active Error Code
130
0x0082
0
Extended Device Status - Type
138
0x008A
1
Extended Device Status - ID
138
0x008A
2
139
0x008B
0
NFC Status
Condition Monitoring [CM]
146
0x0092
0
Condition Monitoring
160
0x00A0
0
Actual Leakage Rate
Parameter ISDU 138 - Extended Device Status
Type
ID
Type Color
0x10
Green
0x0000
0x21
0x0002
Yellow
0x22
0x0007
Yellow
0x22
0x000A
Yellow
0x22
0x0017
Yellow
0x41
0x000C
Orange
0x41
0x000D
Orange
0x41
0x0015
Orange
0x42
0x0010
Orange
0x42
0x0011
Orange
0x42
0x0016
Orange
0x81
0x0000
Red
Implemented IO-Link Events
Event code
Event name
dec
hex
General malfunction
4096 0x1000
Overtemperature
16384 0x4000
General power supply fault
20736 0x5100
20752 0x5110
Primary supply voltage over-run
30480 0x7710
Short circuit
35872 0x8C20
Measurement range over-run
6144 0x1800
Calibration OK
6145 0x1801
Calibration failed
6149 0x1805
Teach-In completed successfully
6150 0x1806
Teach-In command failed
6153 0x1809
Leakage rate above limit
6156 0x180C
Primary supply voltage out of range
J. Schmalz GmbH
V: 999 >= SP2 > rP2
999 >= FH2 > FL2+Hy2
P: 9999 >= SP2 > rP2
2 bytes
9999 >= FH2 > FL2+Hy2
VP: 8000 >= SP2 > rP2
8000 >= FH2 >FL2+Hy2
V: rP2/FL2 >= 0
2 bytes
P: rP2/FL2 >= 0
VP: rP2/FL2 >= -999
1 byte
0 - 1
1 byte
2, 3, 128, 129
0 <= Hy2 <= FH2-FL2
V: Hy2 < 999
2 bytes
P: Hy2 < 9999
VP: Hy2 < 8000
2 bytes
0 - 999
2 bytes
0 - 999
2 bytes
0 - 999
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
1 byte
4 bytes
4 bytes
4 bytes
4 bytes
2 bytes
1 byte
15 x 3 bytes
1 byte
1 byte
2 bytes
1 byte
1 byte
2 bytes
Type Text
Status Text
Everything OK
Everything OK
Warning lower
Leakage rate above limit
Warning upper
Primary supply voltage US outside of operating range
Warning upper
Sensor calibration failed
Warning upper
Teach-In failed
Critical condition lower
Overload OUT1
Critical condition lower
Overload OUT2
Critical condition lower
Overtemperature
Critical condition upper
Primary supply voltage US too low
Critical condition upper
Primary supply voltage US too high
Critical condition upper
IO-Link communication interruption
Defect lower
Internal parameter data invalid
Event type
Remark
Error
Error in internal data (E01)
Error
Overtemperature in electronic circuit (E19)
Error
Primary supply voltage US too low (E07)
Warning
Primary supply voltage US too high (E17)
Error
Overload or short circuit at one or more outputs (E11 and/or E12)
Error
Overflow of sensor value, invalid measurement
Notification
Calibration offset 0 set successfully
Notification
Sensor value too high or too low, offset not changed (E03)
Notification
New values taught for SPx, rPx or FHx, FLx, hyx
Notification
Sensor value over-run, SPx not changed (E20)
Warning
Condition Monitoring: leakage rate above limit
Warning
Condition Monitoring: primary supply voltage US outside operating range
V: 550
rw
P: 5000
VP: 5500
V: 500
rw
P: 4500
VP: 5000
rw
0
rw
3
V: 20
rw
P: 100
VP: 20
rw
0
rw
0
rw
200
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
2 of 2
VSi series
J. Schmalz GmbH
Johannes-Schmalz-Straße 1, D 72293 Glatten
Tel.: +49(0)7443/2403-0
www.schmalz.com
info@schmalz.de
Unit mbar
Unit mbar
0 = NO
1 = NC
2 = Window Mode
3 = Two-Point Mode
128 = Condition Monitoring (not for VSi P10)
129 = Diagnostic Mode
Unit mbar
Unit ms
Unit ms
Unit mbar/sec
Copy of currently active process data input
Actual sensor value
Lowest measured sensor value since power-up
Highest measured sensor value since power-up
Supply voltage as measured by the device (unit: 0.1 Volt)
Lowest measured supply voltage since power-up
Highest measured supply voltage since power-up
0x00 = SIO mode
0x10 = IO-Link revision 1.0 (set by master)
0x11 = IO-Link revision 1.1 (set by master)
Switch-on counter for switch point 1 (non-erasable)
Switch-on counter for switch point 2 (non-erasable)
Switch-on counter for switch point 1 (erasable)
Switch-on counter for switch point 2 (erasable)
Number of errors since last power-up
0 = Device is operating properly
1 = Maintenance required
2 = Out of specification
3 = Functional check
4 = Failure
Information about currently pending events
Fixed-length array format according to IO-Link specification V1.1
0 = No error
1-99 = Error code displayed by the device
Type code of active device status (see below)
ID code of active device status (see below)
Result of recent NFC activity:
0x00: Data valid, write finished successfully
0x23: Write failed: Write access locked
0x30: Write failed: parameter(s) out of range
0x41: Write failed: parameter set inconsistent
0xA1: Write failed :invalid authorisation
0xA2: NFC not available
0xA3: Write failed: invalid data structure
0xA5: Write pending
0xA6: NFC internal error
Bit 2: Leakage rate above limit -L- (not for VSi P10)
Bit 5: Primary voltage US outside of optimal range
Leakage rate, unit mbar/sec (not for VSi P10)