5.6 STOVE LEVELLING
The stove must be levelled, with the help of a spirit
level, by regulating the adjustable feet (if included) fig.
5.10).
A B = Spirit Level
5.7 CONNECTION TO UTILITIES
5.7.1 Electrical connection
It is sufficient to connect the stove to the electrical
system using the supplied plug.
The electrical connection (plug) must be easily
accessible even after installing the stove.
If the power cord is damaged, it must be replaced
by the technical assistance service or by a qualified
technician in order to prevent any risk.
5.7.1.1 Earthing
The system must be earthed and equipped with a
differential switch in accordance with legislation in force
(fig. 5.11).
Make sure the power cord does not come into contact
with hot parts.
The flue gas exhaust pipe must have its own earth
connection.
5.8 OPTIMISATION OF COMBUSTION
Best combustion depends on a variety of factors (type
of installation, operating and maintenance conditions,
type of pellets, etc...)
When first switched on, the stove combustion can be
optimised.
Generally speaking, if at the end of combustion,
there is a lot of residue in the burn pot, you should
change the combustion configuration (by increasing
the value) until you find the best solution.
See sections 9.17- 9.18 - 9.19.
5.9 VENTILATION
The stove is equipped with ventilation.
The air pushed by the fans keeps the appliance at
a low enough temperature, thus avoiding excessive
stress on the materials of which it is composed.
Do not close the hot air outlet vents with any objects
or the stove will overheat!
The stove is not suitable for cooking food.
ATTENTION: Do not cover the air vents.
6
MAINTENANCE
(by an authorised technical assistance centre)
6.1 MAINTENANCE
Maintenance operations must be performed by an
authorised technical assistance centre.
Before performing any maintenance operation, take
the following precautions:
-
Make sure that all the parts of the stove are cold.
-
Make sure that the ashes are completely
extinguished.
-
Use personal protective equipment provided for
16
534
66,5
541
by Directive 89/391/EEC.
-
Make sure that the general line switch is turned
off.
-
Make sure that the power supply cannot be
accidentally reactivated. Remove the plug from
the wall socket.
-
Always use appropriate equipment for
maintenance.
-
Once the maintenance or the repair operations
are completed, before re-commissioning the
71
489
10/2021 - EN