10.5 Exemple de programmation 5 :

CR1000 mode RS-232 pour le SR50A

'CR1000 Series Datalogger
'In this example, the SR50A is mounted 2.5 meters above the ground.
'The SR50A is used in RS-232 mode (internal jumpers are set).
'The CR1000 sends a serial string to the SR50A, which is in "Measure on Poll Mode",
'and then receives a serial string in return which is parsed into different values.
'Wiring: Black: Power Ground
'
clear: Power Ground
'
Red: +12V,
'
White:C1
'
Green:
'Declare Variables
'Declare SR50AData as a dimensioned string of maximum 50 chrs
Dim
SR50AData as STRING * 50
Public
ParseVals(5) as FLOAT
Alias
ParseVals(1)=SerialAddress
Alias
ParseVals(2)=Raw_Distance
Alias
ParseVals(3)=SignalQuality
Alias
ParseVals(4)=Diagnostics
Alias
ParseVals(5)=Chcksum
Public
Temp_Corr_Distance
Public
Air_Temp
Public
Snow_Depth
'Declare the initial distance of the SR50A from the ground in meters:
Const
Initial_Distance=2.5
'Define Data Tables
DataTable
(Table1,True,-1)
DataInterval
(0,60,Min,10)
Sample
(1,Snow_Depth,FP2)
EndTable
'Main Program
BeginProg
'Open RS232 port for communications 9600 BAUD is the default:
SerialOpen
(Com1,9600,0,0,2000)
Scan
(60,Sec,0,0)
'Measure the SR50A:
'Transmit serial command "p33<CR>"
SerialOut
(Com1,"p33"+chr(13),"",0,0)
C2
- 50 -