4.4. Influence of climatic conditions

During application, some factors may determine the interruption of the spraying.
Wind currents, for example, can cause spray to drift and not reach the target de-
pending on the size and weight of the droplets. The temperature and especially
the relative humidity contribute to the rapid evaporation of the droplets.
The ideal conditions for spraying are:
• Relative humidity: minimum 50%;
• Wind speed: 3-10 km / h;
• Temperature below 30 C.
These limits should be considered according to technical application that will
be used, adopting the safest class drops within the boundaries of each situation.
Air velocity
around the nozzle
Description
height
Up to 2km/h
Calm
2 to 3 km/h
Nearly calm
Slight movement of the leaves.
3 to 7 km/h
Light breeze
Leaves and thin branches in
7 to 10 km/h
Light wind
Branches are moving. Dust and
Moderate
10 to 15 km/h
pieces of paper are carried by
wind
Classes of drops according to weather conditions
Factors
Very fi ne or fi ne
Temperature
below 25º C
Relative humidity
above 70%

4.5. Disposal of waste products

The elimination of waste resulting from the dismantling of equipment during ser-
vice, maintenance or end of life (disposal) should be carried out respecting the
environment, preventing pollution of air, soil and water. If necessary, the waste
should be stored in appropriate locations and then transported by qualifi ed and
trained people and companies.
Disposal of used sprayer should be done at appropriate points and approved for
receiving such material. If there isn't an appropriate nearby site, please contact the
Customer attendance: Dr. Luiz Miranda, 1650, 17580-000 – Pompeia – SP – Brazil.
Phone: +55 14 3405 2113. Email: assistencia.tecnicajsfs@jacto.com.br
Opening Hours: Monday to Friday 7:00am to 11:30am and 13:00pm to 17:18pm
(Brazilian time zone).
0.8 Bar (11.6 psi)
1.0 Bar (14.5 psi)
1.2 Bar (17.4 psi)
1.3 Bar (18.8 psi)
1.5 Bar (21.7 psi)
1.7 Bar (24.6 psi)
1.8 Bar (26.1 psi)
2.0 Bar (29 psi)
2.3 Bar (33.3 psi)
2.8 Bar (40.6 psi)
3.0 Bar (43.5 psi)
3.2 Bar (46.4 psi)
Visible signs
Visible signs
Smoke rises vertically
Recommended only with
course, very course drops
The smoke is tilted
Ideal for spraying
Feel the light wind
We recommend only the
constant motion
drift reduction technique
Improper for spraying
the wind
Fine or medium
Medium or course
25 to 28º C
above 28º C
60 to 70%
below 60%

5. Information Needed by User

5.1. Troubleshooting

• Put about 2 liters of water in the tank.
• While operating the lever, look into the tank to see how the problem arises.
• Refer to the table and diagram below.
DESCRIPTION
Leakage through the cylinder
Worn or dried out piston cup.
upper part.
After pumping and pressurizing
Cylinder valve not sealing
the chamber, as you operate the
properly due to wear or
.
lever drops fast
Válvula da câmara com
After pumping and pressurizing
defi ciência de vedação por
the chamber, the lever rises
desgaste ou Chamber valve not
quickly when released.
sealing properly due to wear or

5.2. Maintenance of the product

Every 40 hours, clean the chamber and lubricate all the components. Using a pair
of pliers, disassemble the parts. Clean the parts using a nylon bristled brush and
liquid detergent. Always use personal protective equipment (PPE).

5.3. Cleaning the sprayer

After fi nishing the spray application, clean and wash all equipment in an approved
decontamination area.
Add a small amount of clean water in the tank and operate the lever to clean the
internal system parts of the sprayer.
Remove the chamber and lubricate the piston.
5.4. Draining
Drain the sprayer after you have fi nished using it.

5.5. The consequences of improper service

Do not alter the sprayer components. Always check for leaks or malfunction. Fol-
low the maintenance instructions and use original parts provided by Jacto.
Failure to follow the instructions may cause damage to the operator's health and
the environment.
CAUSES
CORRECTIONS
Replace or lubricate the
piston cups.
Clean or replace the valve.
impurities.
Clean or replace the valve.
impurities. impurezas