Ordinary maintenance is not included in the warranty.
Proper use of the appliance and proper and regular maintenance are essential to ensure better performance and longer
service life.
before carrying out any maintenance operations, make sure that the gas tap has been closed and that
the appliance is cold; For all routine and / or extraordinary maintenance work, consult only
professionally qualified personnel, or rather the KEMPER Technical Support Center
At least once a year before the start of the season, it is recommended that:
•
Gas pipe replacement if damaged
•
Replacing the worn parts of the heater
•
External heater cleaning with wet soft cloth, not inflammable or corrosive solvents
Depending on the quality of the type of gas used, it is possible that the glass tubular obscures due to the
components added to the propane gas mixture and generally to the dirt; for the internal cleaning of the glass
tube you can use a soft cloth, restoring the initial transparency.
If you need to replace the glass tube (important blackening after a few years, or accidental breakage) proceed as
follows:
- wait until the heater is cold, in all its parts
- Remove hat by acting on the 3 bolted links (cross head) M5 placed on the top of the hat
- remove the broken glass tube - PAY ATTENTION
- reassemble hat
If glass cleaning is required, proceed as follows:
•
Wait until the heater is cold, in all its parts
•
Remove hat by acting on the 3 bolted links (cross head) M5 placed on the top of the hat
•
remove the broken glass tube - PAY ATTENTION
•
Use a wet cloth to clean the inside of the glass by gently passing it from one end to the other until the glass
returns clean
•
Put the glass back in its position and reassemble the hat
MANDATORY; the heater must be carried / moved only when it is cold and in the absence of gas tank
(safety and protection components).
Anomalies
A Pilot ignite, main burner
does not ignite
B Continuous spark,
the pilot does not ignite
C The pilot ignites and then
shuts off as soon as
the tap is released
D There is no spark at the
pilot ignition
E Lack of flame
F Glass tube blackening
Page | 30
MAINTENANCE
Periodic maintenance
Glass tube replacement
Glass tube cleaning
Anomalies, possible causes and remedies
Possible causes
A1 Gas tap anomaly
B1 Lack of gas
B2 Pilot cluster obstruction
B3 Thermocouple anomaly
B4 Anti tilt sensor blocked
C1 Thermocouple anomaly
D1 Damaged discharge electrode
D2 Disconnected discharge cable
E1 Bad LPG gasification
E2 Thermocouple interrupted
E3 Obstructed gas circuit
E4 Leaks in the gas circuit
E5 Gas regulator to be replaced
F1 Low quality gas
F2 Bad draft
F3 Dirty burner
Remedies
A1 Replace the gas tap
B1 Check opening of the gas tap, on the
gas tank, check gas adaptor
B2 Clean the pilot cluster (qualified personnel)
B3 Replace thermocouple
B4 Replace anti tilt sensor
C1 Replace thermocouple
D1 Electrode replacement
D2 Reconnect with its faston
E1 Replace the gas tank
E2 Replace the thermocouple
E3 Clean the gas circuit
E4 Fix any leak
E5 Replace the gas regulator
F1 Use better quality gas
F2 Check for wind presence
F3 Clean the burner with low pressure air
EN