7 - Electrical supply

EN
Before installing the oven have a qualified electrician verify
that your home is provided with adequate electrical service
and that the addition of the oven will not overload the branch
circuit on which it is to be installed.
Be sure your appliance is properly installed and grounded
by a qualified technician. Ask your dealer to recommend a
qualified technician or an authorized repair service.
This appliance is manufactured with a green GROUND wire
connected to the oven chassis Junction Box or Wall Receptacle
Location.
Suggested location of the junction box or wall receptacle is
showed in "Cutout requirements" Figure.
LOCATION OF RATING PLATE
Your local codes and ordinances, of course, take precedence
over these instructions. Complete electrical connections
according to local codes and ordinances.
A UL listed conduit connector must be provided at each end of
the power supply conduit (at the range and at the junction box).
• Wire sizes and connections must conform with the rating of
the range.
• The wiring diagram is located on the back of the range or
in a clear plastic bag.
In the United States:
Be sure that the electrical and grounding connections and also
wire size are adequate and in conformance with the National
Electrical Code, ANSI/ NFPA 70-latest edition and all local
codes and ordinances.
In Canada:
Be sure that the electrical connection and wire size are
adequate and in conformance with CSA Standard C22.1,
Canadian Electrical Code, Part 1 - latest edition, and all local
codes and ordinances.
WARNING
Risk of Electric Shock, frame grounded to neutral of appliance
through a link
20
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or in an area where local codes prohibit
grounding through the neutral conductor. For installations
where grounding through the neutral conductor is prohibited:
- Disconnect the ground from the neutral at free end of conduit;
- Use grounding terminal or lead to ground unit; and
- Connect neutral terminal or lead to branch circuit neutral in
usual manner.
A 3-wire* or 4-wire single phase 120/240 or 120/208 Volt,
60 Hz AC only electrical supply is required on a separate
circuit fused on both sides of the line (time-delay fuse or circuit
breaker is recommended). DO NOT fuse neutral.
NOTE: FOR USE WITH 208 V, 60 HZ SUPPLY VOLTAGE, SEE
CONNECTING TO 208 VOLT CIRCUIT.
ELECTRICAL REQUIREMENTS 30" or 36" OVEN RANGE
Electrical Supply
120-240V or 120-208V, 60 Hz
Service
30 amp dedicated circuit
Total Amps
120/240V 16.5
120/208V 18.2
Max Connected Load
120/240V 3.83
120/208V 3.68
Min Supply Wire
L1, L2, ground
Neutral
WARNING
ELECTRICAL SHOCK HAZARD
• The electrical power to the appliance branch circuit must
be shut off while line connections are being made.
• Do not use an extension cord with this appliance.
• Electrical ground is required on this appliance.
• The free end of the green wire (the ground wire) must be
connected to a suitable ground. This wire must remain
grounded to the appliance.
• If cold water pipe is interrupted by plastic, non metallic
gaskets, union connections or other insulating materials,
DO NOT use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the NEUTRAL or GROUNDING
circuit. A fuse in the NEUTRAL or GROUNDING circuit
could result in an electrical shock.
• Check with a qualified electrician if you are in doubt as to
whether the appliance is properly grounded.
• Failure to follow these instructions could result in serious
injury or death.
Amps
Amps
kW
kW
12 AWG
16 AWG