PNI GD-01 + V-02 Manuel Utilisateur page 6

Détecteur de gaz et électrovanne

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
EN
4. The solenoid control wires must be connected correctly. The white thread is positive and the black thread is
negative. Making an incorrect connection can lead to a risk of short circuit.
5. During maintenance work on the gas pipe, such as cleaning the pressure pipe, the solenoid valve must be
removed to avoid damaging it.
6. During pressure tests, the solenoid valve must be opened.
7. The solenoid valve opening button can be pulled vertically upwards when the pressures are equal (inlet and
outlet).
8. Reverse polarity and incorrect voltage can damage the solenoid coil of the solenoid valve.
9. It is recommended to install together with the gas sensor in the kit. The connection is made plug & play (plug
in plug), without other modifications.
PRECAUTIONS
1. If screws and washers come in contact with water or chemicals, it is necessary to clean them to prevent
corrosion.
2. If the product is installed completely or partially outside, protection against water is recommended
3. The transparent cover has the role of protection against accidental actuation of the red button.
CONNECTING THE SENSOR WITH THE SOLENOID VALVE
Connecting the gas sensor with the solenoid valve is plug-in without other adjustments, but both products
can be adapted for other devices such as solenoid valve, respectively sensor if the plug system is changed.
Cable recommendations:
1. Cable: two-wire, 2 x 0.3 mm² or larger
2. Cable length <20 meters
6