This operation must be carried out by qualified staff, at an assistance centre.
Level-control solenoid valve connection
Connect the solenoid valve power supply cable to the OUT 3 clamp (N and F).
Output protected with a safety fuse. If the fuse blows, a red led will light up in the level-control
solenoid valve indicator light on the front synoptic panel.
ATTENTION: the output voltage of the OUT3 clamp is 220Vac. To connect the solenoid valve at
24vac use the designated solenoid valve transformer kit TR324 code 100100835
CODE
F5
F6
F8
F9
CAUTION!! Wiring and connection operations must be carried out by qualified staff. Only use
pumps with internal over-heating protection systems.
Mechanical parts
[OPERATION AND MAINTENANCE HANDBOOK
Description of protection fuses
FUNCTION
Lighting fuse
Filtration pump fuse
Level-control solenoid valve fuse
Internal electronic fuse
Periodic Maintenance and Checks
]
[V-1.16]
FUSE VALUE
250 V - T 3.15 A
250 V - T 16 A
250 V - T 3.15 A
250 V - T 1 A
AQUA spa