Potential for false alarms
You can silence the FlammEx gas detector by pressing
the test button. The red LED will continue to flash
and a short alarm will sound approximately every 45
seconds. To fulfil its purpose and to ensure your safety,
the FMG 3637 FlammEx gas detector is designed to be
highly sensitive. The system's sensor may also react to
other gaseous media. The use of aerosols (propellants
in spray cans), as well as thick smoke and cooking
vapours, may trigger a false alarm.
Technical data
Mains voltage
Electricity consumption
Ambient temperature
Relative humidity
Response threshold
Calibrated acc. to
Signal volume
Alarm output
Dimensions
Technical and design features may be subject to change without notice.
230 V ~, 50 Hz
approx. 3.4 W
0 °C ...+50 °C
5 % - 95 %
approx. < 5% of the lower explosion limit
EN 50194-1
approx. 85 dB/3 m
9 V /20 mA
approx. W 80 x H 156 x D 51 mm
Recycling instructions
This device may not be disposed of with unsorted
household waste. Owners of old devices are
required by law to dispose of this device correctly.
Contact your town council for further information.