ELECTRICAL CONNECTION:
The electric power supply for the machine is available in 2 single-phase voltages:
- 110-120 V 50/60 Hz: model 48V1 and 49V1
- 220-240 V 50/60 Hz: model 48 and 49
Line protection: the machine should be connected to a standard 2-pole + earth electric
socket. The system should be fitted with a ground fault circuit interrupter and a fuse rated
at 16A. The appliance must be earthed.
CARE:
Before connecting the machine, check that the mains electrical voltage
is the same as the voltage for your machine. This value is given:
!
either on the identification plate under the machine.
or on the identification plate on the last page of this manual.
If the power supply lead is damaged, it must be by a special assembly available from
approved SANTOS dealers or from SANTOS.
Check that the On / Off switch (11) is in the 0 position before connecting the
CARE:
power supply lead plug to your mains electric power socket.
!
98148 US 3.2 - 12 2010
408100-200 en ma 2010.12
6 / 14
www.santos.fr