General Safety Instructions
Read this operating instruction carefully before use!
Improper handling of Lithium Batteries may cause fire,
explosion or chemical danger. Check battery manufacturer
instructions.
Charge only Li-Ion battery packs. Do not charge Lead Acid-,
NiCd- NiMh or non-rechargeable primary batteries. Connect
the charger to a suitable mains supply, only. Disconnect the
charger from mains and the battery pack if it is not in use for
a longer time.
The charger is designed for usage in a damp-free, dry and
ventilated environment. Do not expose the charger to rain
or hot conditions. Don't cover the charger. Please keep the
charger clean and dry.
Do not charge hot battery packs. Battery packs must be at
ambient temperature before charging.
Do not use the charger if there are any signs of damage.
Do not open the charger or carry repairs. Repairs may be
carried from authorized personal with original spare parts,
only.
Content
1. Charger with dc cable
2. AC Power cord
3. Operating instructions
Functions
1. This charger is suitable to charge a 58.8 Volt Li-Ion battery pack. The max. charge current is
2.5 A.
2. The charger has an overload, short circuit, overvoltage and wrong polarity protection.
3. The charger has an internal temperature control that protects the charger at too high ambient
temperature as well as continuous overload. If this happens the charger will reduce the output
power.
4. Errors are shown by the flashing red LED.