GAS PIPING
Gas piping shall be of such size and so installed as to provide a supply of gas sufficient to
meet the full gas input of the appliance. If the appliance is to be connected to existing piping,
it shall be checked to determine if it has adequate capacity. Joint compound shall be used
sparingly and only on the male threads of the pipe joints. Such compounds shall be resistant
to the action of L.P. gases.
WARNING: Any loose foreign material, debris, or metal particles allowed to enter the gas lines
on this appliance will damage the valve and affect its operation. When installing this appliance,
all pipe and fittings must be free from all internal loose dirt.
GAS PRESSURE REGULATOR
A convertible pressure regulator is provided with each charbroiler. It should be connected to
the inlet pipe at the rear of the unit. The gas supply is then connected to it. It is shipped set for
6" water column manifold pressure for use with natural gas. Allow 6" clearance from back of
unit to wall for servicing and installation.
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed upstream from the manifold and within six feet of
the charbroiler.
CONNECTING GAS SUPPLY LINE
The gas inlet of the charbroiler is sealed at the factory to prevent entry of dirt. Do not remove
this seal until the actual connection is made to the gas supply line.
PROPANE GAS
This charbroiler is equipped with fixed orifice hoods and is shipped from the factory for use
with natural gas. To convert to propane gas, install the burner orifice hoods, included with the
unit, as follows:
. Remove grill, radiants and burners.
2. Remove the burner orifice hoods and install the orifice hoods supplied.
. Replace the burners, radiants, and grill.
4. Set manifold pressure to (0) inch water column. A /8" pipe plug on the burner manifold
can be removed for attaching a pressure gauge. Remove the slotted, or hex-threaded plug
from the pressure regulator. Invert the plug and re-install. The letters "LP" should now be
visible on the plug. The regulator is now set for 0" (5.4 cm) water column. Attach the
conversion label, supplied with the unit, close to the nameplate.
CHECKING FOR GAS LEAKS
Check entire piping system for leaks. Soap and water solution or other material acceptable for
the purpose shall be used in locating gas leakage.
Matches, candle flame or other sources of ignition shall not be used for this
purpose.