STEP 10 INSTALL WATER LINE
SmartConnect ™ Refrigerator Tubing Kits are available in
the following lengths:
6' (1.8 m)
– WX08X10006

STEP 11 CONNECT WATER SUPPLY

A cold water supply is required for automatic ice maker
operation. If there is not a cold water supply, you will need
to provide one. See Installing the Water Line section.
NOTES:
• Before making the connection to the refrigerator, be
sure the refrigerator power cord is not plugged into
the wall outlet.
• If your refrigerator does not have a water filter,
we recommend installing one if your water supply
has sand or particles that could clog the screen of
the refrigerator's water valve. Install it in the water
line near the refrigerator. If using SmartConnect ™
Refrigerator Tubing Kit, you will need an additional
tube (WX08X10002) to connect the filter. Do not cut
plastic tube to install filter.
• Before connecting the water line to the house, purge
the house line for at least 2 minutes.
A. If you are using copper tubing, place a compression
nut and ferrule (sleeve) onto the end of the tubing
coming from the house cold water supply.
If you are using the SmartConnect ™ tubing, the nuts
are already assembled to the tubing.
WARNING
Electrical Shock Hazard.
Attach tubing clamp using existing hole only. DO NOT
drill into the refrigerator.
AVERTISSEMENT
Fixez le collier de serrage dans le trou présent seulement. NE
PERCEZ PAS dans le réfrigérateur.
ADVERTENCIA
ELÉCTRICA
Adhiera la abrazadera de la tubería usando el
agujero existente únicamente. NO perfore el refrigerador.
SmartConnect ™ Tubing
Refrigerator
Connection
31-1000551 Rev. 0
Installation Instructions
RISQUE DE DÉCHARGE
ÉLECTRIQUE
PELIGRO DE DESCARGA
1/4" Compression
Nut
Ferrule
(sleeve)
15' (4.6 m)
– WX08X10015
25' (7.6 m)
– WX08X10025
B. If you are using copper tubing, insert the end of the
tubing into the refrigerator connection, at the back of
the refrigerator, as far as possible. While holding the
tubing, tighten the fitting.
If you are using SmartConnect ™ tubing, insert
the molded end of the tubing into the refrigerator
connection, at the back of the refrigerator, and
tighten the compression nut until it is hand tight.
Then tighten one additional turn with a wrench. Over
tightening may cause leaks.
C. Fasten the tubing into the clamp provided to hold it
in position. You may need to pry open the clamp.
D. Turn on the water at the shut-off valve to check
for leaks.
WARNING
Connect to potable water supply only. A
cold water supply is required for automatic icemaker
operation. The water pressure must be between 40 and
120 psi (275-827 kilopascals).
AVERTISSEMENT
eau potable seulement.
Une alimentation en eau potable est requise pour le
fonctionnement de la machine à glaçons. La pression d'eau doit
se situer entre 40 et 120 psi (275 à 827 kilopascals).
ADVERTENCIA
Realice la conexión a un suministro de agua potable únicamente.
Se requiere un suministro de agua fría para el funcionamiento
de la máquina de hielos automática. La presión del agua deberá
estar entre 40 y 120 psi (275-827 kilopascales).