G 2
B AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED MODULE
SAFETY PRECAUTIONS
-
Always disconnect the power supply before installing or making modifications to the devices.
-
The fitting and handling of these devices must be carried out by
-
The wiring must run at least 40 cm away from any other wiring.
( )
CHARACTERISTICS
*
-
Coded keypad module for GB2 coded door panel systems.
-
Can be combined with 'Nexa Modular' and 'Inox Modular' door panels.
-Enables calls to be made to the building's apartments by entering an assigned code.
-Enables activation of the relay of the door release connected to the EL632/GB2A module by
means of an access code.
-Enables configuration of the GB2 system's options shown in the table on page 4.
( )
DESCRIPTION OF THE MODULE
*
a
b
c
d
a. Front.
b.
Numeric keypad.
c.
Bell button.
d.
Cancel button.
Connection terminals:
+ -
:
Positive, negative (22 Vdc output maximum 100 mA)
( )
CONNECTION OF THE MODULE
*
N3301/GB2
( )
For more information, see the "TCODE/CA GB2 user manual (code
*
https://doc.golmar.es/search/manual/50122371
2
authorised personnel
.
e
f
g
e. Back.
f.
Terminal strip connector for 22 Vdc output.
g.
Socket for connection with the EL632/GB2A.
_
+
C1 NA1
AP-
AP+
NA2
C2 AP+ AP- P1 P2 BUSBUS
Relay 1
Relay 2
12Vdc
EL632/GB2A
50122371)".
G 2
B AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED MODULE
PROGRAMMING THE DOOR PANEL
( )
*
Programming mode entry and exit:
To enter programming mode, press the bell button (N3301/GB2), followed by the administrator code
'1234', and finally confirm by pressing the bell button (N3301/GB2) again.
' ell (N3301/GB2)' + 'administrator code' + 'bell (N3301/GB2)'.
b
To exit programming mode, press the C button (cancel) once if it is in a programming field or twice if
not.
If no button is pressed within 10 seconds, it exits programming mode.
Programming mode entry and exit is confirmed by the emitting of a long and short tone.
Programming mode structure and sequence:
Programming of the keypad functions is performed by entering the field or function code, followed by
the bell button (N3301/GB2) and the field value.
Once in programming mode, the programming sequence is as follows:
Enter the code of the field to be programmed: this code is always 2 digits. To confirm,
0
3
press the bell button (N3301/GB2) and the keypad will emit a long and then short
tone indicating that the field to be programmed is correct or three short tones if the
indicated programming field does not exist.
Enter the value of the field being programmed. Once the value has been entered,
0
5
press the bell button (N3301/GB2) and the door panel will emit a long confirmation
tone if the information entered is correct or three short tones if it is not correct.
Note: If no key is pressed within 10 seconds, it will be necessary to enter the
programming code and select the programming field again.
Enter the code of the following field or press the C button (cancel) to exit programming
0
1
C
or
mode.
If wrong information is entered or an access or administrator code is repeated, the door panel will
emit three short tones to indicate that the information is incorrect. If the field code to be
programmed was being entered, the programming code must be re-entered; if the field value was
being entered, the field value being configured must be re-entered.
Field
Programming
03
mode entry
sequence
C
2
( )
For more information, see the "TCODE/CA GB2 user manual (code 50122371)".
*
https://doc.golmar.es/search/manual/50122371
1
2
3
4
Field value
05
2
C
C
C
3
1