11 END POINTS / EXPONENTIAL
2 CARACTERISTIQUES
Your transmitter offers advanced End Point settings for each channel as well as Exponential settings, grouped in the EP:EX
menu.
To access this menu, press the EXIT button and turn on the transmitter.
The EP:EX menu is displayed on the screen, indicating that you can adjust EXPO and End Points for each channel
(channels 1, 2 and 4).
Press ENTER or EXIT button to enter the sub-menu as shown in the graph below.
11.1 END POINTS
1/ Press EXIT and turn on the Transmitter. The EP:EX menu displays.
2/ Press ENTER to access End Points setting. EPA displays for 1 second then the travel range appears for channel 1, set to
default value 100%.
3/ Select the channel you want to set by pressing ENTER multiple times, the number of the channel scrolls on the top of
the screen : 1, 2, 3, 4, 5, 6.
4/ Press UP or DOWN to set the value from the following choices :
50%, 60%, 70%, 80%, 90%, 100%, 110%, 120%,See the concerned servo reaction as you change the value.
5/ Press EXIT to save your settings and exit the menu. You will need to reboot your Tx to use it once the setting is done.
i
Note that this setting act on the total range of the servo and you can combine it with the Dual Rate value.
11.2 EXPO
1/ Press EXIT and turn on the Transmitter. The EP:EX menu displays.
2/ Press EXIT to access the EXPO sub menu. EXP displays for 1 second then the EXPO RATE appears for channel 1, set to
default value 0%
3/ Select the channel you want to set by pressing ENTER multiple times, the number of the channel scrolls on the top of
the screen : 1, 2, 4.
4/ Press UP or DOWN to set the value from the following choices : -60%, -45%, -30%, -15%, 0%, 15%, 30%,
45%, 60%. See the concerned servo reaction as you change the value.
5/ Press EXIT to save your settings and exit the menu. You will need to reboot your Tx to use it once the setting is done.
EXIT
ENTER
EXIT
ENTER
43