Model: ADQ36006108-S
The concentration of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible limit for water leaving
the system as specified in NSF/ANSI Standard 42 and Standard 53.
System tested and certified by NSF International against NSF/ANSI
Standard 42 and Standard 53 for the reduction of substances listed
below.
Substance
Average
Reduction
Influent
Chlorine Taste and
1.9 mg/L
Odor
Nominal
6,866,667 pts/
Particulate Class I,
, ≥ 0.5 to < 1.0 µm
Asbestos
260 MFL
Atrazine
0.0010 mg/L
Benzene
0.014 mg/L
Carbofuran
0.09 mg/L
Lindane
0.002 mg/L
P-Dichlorobenzene
0.23 mg/L
Toxaphene
0.014 mg/L
2,4-D
0.222 mg/L
Lead pH @6.5
0.147 mg/L
Lead pH @8.5
0.150 mg/L
Mercury @ pH 6.5
0.0059 mg/L
Mercury @ pH 8.5
0.006 mg/L
97,500
Cyst*
cysts/L
* Based on the use of Cryptosporidium parvum oocysts.
Performance Data Sheet
NSF specified
Challenge
Concentration
2.0 mg/L ± 10%
At least 10,000
mL
particles/mL
10
to 10
MFL;
7
8
fibers greater
than 10 µm in
length
0.009 mg/L
± 10%
0.015 mg/L
± 10%
0.08 mg/L
± 10%
0.002 mg/L
± 10%
0.225 mg/L
± 10%
0.015 mg/L
± 10%
0.210 mg/L
± 10%
0.15 mg/L
± 10%
0.15 mg/L
± 10%
0.006 mg/L
± 10%
0.006 mg/L
± 10%
Minimum
50,000 cysts/L
Use Replacement Cartridge: ADQ36006108
Average
Avg %
Product Water
Reduction
Concentration
84.9%
0.29 mg/L
99.7%
23,417 pts/ml
>99%
< 1MLF
95.0%
0.0005 mg/L
96.6%
0.0005 mg/L
98.9%
0.002 mg/L
99.1%
0.00002 mg/L
99.8%
0.0005 mg/L
93%
0.001 mg/L
94.5%
0.012 mg/L
>99.3%
0.001 mg/L
>99.3%
0.001 mg/L
96.1
0.0002 mg/L
92.6
0.0005 mg/L
99.99%
13 cyst/L
Max
NSF
Permissible
Reduction
Product Water
Requirements
Concentration
N/A
≥ 50%
N/A
≥ 85%
N/A
≥ 99%
0.003 mg/L
N/A
0.005 mg/L
N/A
0.001 mg/L
N/A
0.0002 mg/L
N/A
0.075 mg/L
N/A
0.003 mg/L
N/A
0.070 mg/L
N/A
0.010 mg/L
N/A
0.010 mg/L
N/A
0.002 mg/L
N/A
0.002 mg/L
N/A
N/A
≥ 99.95%
NSF Test
Report
J-00126243
J-00117747
J-00126246
J-00117748
J-00117749
J-00117751
J-00126254
J-00126248
J-00126249
J-00126247
J-00126252
J-00126253
J-00126253
J-00126251
J-00123282