3.
Recess Mount the Cabinet
Mounting Holes
Orifices de fixation
Orificios de fijación
NOTICE: When determining the height of the product, ensure the mirrored door will
clear all obstacles (such as a faucet).
NOTICE: Install the panhead screws to a stud to avoid possible property and
product damage. If this is not possible, anchors (provided) must be inserted into the
finished wall before installing the panhead screws.
Measure and mark the cutout 14" (35.6 cm) in width and 18" (45.7 cm) in length
between two framing studs.
Verify the marked cutout is level and plumb.
Using a jigsaw or keyhole saw, remove the finished wall material from the marked
cutout.
With assistance, place and hold the cabinet into the cutout.
Open the door.
Mount the cabinet to the framing studs using a #10 x 1-1/2" panhead screw
(provided) through each of the four mounting holes.
Cover each mounting screw with a hole plug (provided).
Encastrer le meuble
NOTICE: Lors de la détermination de la hauteur du produit, s'assurer que la porte à
miroir dégage tout obstacle (tel que robinet).
1085925-2-A
Wall Cutout
Découpe du mur
14" (35.6 cm)
Abertura de la pared
18" (45.7 cm)
Hole Plug
Bouche rainure
Tapón del orificio
6