(A) INTRODUCTION
Rainfresh UV systems make water safe to drink by instantly destroying
pathogenic bacteria (such as coliforms, E. coli, viruses etc.). These systems
utilize the proven disinfection properties of ultraviolet light (UV) emitted at 254
nm wavelength. UV systems are used by many municipalities in Canada and
around the world as a primary disinfectant as it is a natural, non-chemical,
environmentally safe technique that does not form any harmful disinfection by-
products.
HOW THE RAINFRESH UV WATER DISINFECTION SYSTEM WORKS
Your Rainfresh UV system consists of a low-pressure UV lamp enclosed in a
transparent quartz dome, housed in a stainless steel disinfection chamber. As
untreated water enters the chamber from one end, pathogenic microorganisms
in the water are exposed to and instantly destroyed by ultraviolet light emitted
by a specially engineered UV lamp. Treated water flows out of the chamber and
is ready for consumption. See Fig. 1
(B) SAFETY INSTRUCTIONS
Contains mercury
o To avoid possible electric shock, extra care should be taken since water may be present near electrical
equipment. Unless specifically referred to in these instructions, do not attempt repairs yourself. Do not plug the
unit in if any electrical surfaces or electrical parts are wet.
o DO NOT LOOK DIRECTLY AT UV LAMP WHEN LAMP IS ON. UV light can cause serious burns to eyes and skin.
o Do not operate the UV lamp outside the UV disinfection chamber.
o Do not use this unit for any purpose other than its intended use for potable water disinfection. The use of
attachments not recommended, approved or sold by the manufacturer may result in improper performance of
the unit or an unsafe condition and void the product warranty.
o Do not operate the system if it has a damaged electrical cord or plug, is malfunctioning, or has been damaged in
any way.
o Do not touch the lamp or quartz dome with dirty or moist hands. Hold the lamp and dome by the ends with soft
dry gloves or cloth.
o Before any cleaning or maintenance on the system, always unplug the unit from the power source.
o Disconnect power cable from the power outlet by holding the plug. Never pull the cord.
o To comply with the National Electrical Code and to provide additional protection from the risk of electric shock,
this system should only be connected to a properly grounded, grounding-type controller receptacle that is
protected by a Ground Fault Circuit Interrupter (GFCI).
o Ensure that the lamp connector ground wire is connected to the grounding stud on the chamber.
o Installation of the UV disinfection system and water filter will interrupt electrical grounding continuity of your
plumbing system. For directions on restoring the electrical grounding continuity, consult a certified electrician
o Protect your unit from freezing and weather elements.
To ensure continuous protection, UV LAMP MUST BE REPLACED ANNUALLY. After 1
o
year of use, it will no longer provide effective disinfection even though it stays lit.
USE ONLY GENUINE RAINFRESH UV LAMPS. Use of non-Rainfresh UV lamps can
o
result in unsafe drinking water and will void your product warranty.
 Lamp contains mercury (Hg).
 Dispose or recycle in accordance with applicable laws.
 For information on safe handling procedures and safe disposal and recycling, consult :
https://www.ec.gc.ca/mercure-mercury/default.asp?lang=En&n=D2B2AD47-1