Default settings
Flash detection mode: type approved.
Conversation privacy: on.
Conversation length: 60 s.
Door lock release triggering time: 1 s.
Mode: systems with analogue call.
Programmed code for connection in
systems with coded call: 80155.
Flash interception: disabled.
Type of monitor combined with the
telephone: XV/200.
Entering and exiting the
programming functions
In order to enter programming mode via
the telephone connected to the telepho-
ne interface:
Make sure the receiver is
hung up.
Set dip-switch 1 to OFF.
ON
ON
OFF
1 2 3 4 5 6
During this phase, one or more program-
ming procedures can be carried out in a
row.
The programming codes must be entered
during the pause in the programming tone.
In order to exit programming mode:
Set dip-switch 1 to ON.
ON
ON
1 2 3 4 5 6
OFF
Once finished, when the
receiver is lifted or hands-
free button pressed, the
dial tone must be heard.
PROGRAMMING
Conversation privacy mode
Following this operation, a double tone
should sound, prompting you to commence
programming.
Once finished, you should hear a triple tone
confirming the setting.
29
Lift the receiver
or
press the hands-free key.
2
9
Key in 29.
Press 0 for the no-privacy
0
mode
or
1 for the privacy mode.
1
Replace the receiver
or
press the hands-free key.