CLOSES AGAIN
3
AFTER THE
PHOTOCELL
4
NO REVERSE
PRE-
5
FLASHING
6
FOTOTEST
MASTER/
7
SLAVE
8
OPTIONAL LIMIT SWITCHES (CABLES 25 - 27)
NOT CONNECTED:
CONNECTED
To change the position of Dip 8, the power must be disconnected. Once modified, rerun
the SetUp of the stroke
9-10-11
Automation type selection
Dip 9
Dip 10
Off
Off
On
Off
Off
On
On
On
Off
Off
On
Off
Off
On
On
On
IMPORTANT: In case the automation type change, a new setting of the dips # 9, 10 and
11 will be required. Before the new setup, however, it is necessary to proceed to a HARD
RESET (see pag. 25) of the controller.
SENSITIVE
12
EDGE
6. MEMORIZATION PROCEDURE OF THE STROKE
WARNING: After powering the control panel, wait 2 seconds before you start performing the
adjustment operations and check:
- The Input connections: all green LEDs DL6, DL5, DL4 and DL3 must be on steady.
- The mechanical stops of the automation must be installed and adjusted both in opening and
in closing [see motor instructions].
after the photocell is activated (input 7 - 9), the automation closes au-
On
tomatically after 5 seconds.
Off
function off.
the automation ignores the closure command during opening and
On
auto-close time
Off
the automation responds as established by dip switch No. 2.
On
the pre-flashing function is enabled.
Off
the pre-flashing function is disabled.
On
the "photocell test" function is enabled.
the "photocell test" function is disabled.
Off
Note: to be used when the photocells are not used.
enables the MASTER mode in the master/slave configuration (see T-
On
COMM instructions).
enables the SLAVE mode in the master/slave configuration (see T-
Off
COMM instructions), or standard operation (single motor).
once the mechanical stop of the closing maneuver is reached, the au-
On
tomation makes a slight movement in the opposite direction to avoid
jamming between the rack and the pinion.
Off
function deactivated
On
operation for gate with opening to the left (gearmotor side);
Off
operation for gate with opening to the right (gearmotor side);
Dip 11 Automation
Off
T-ONE10B For gates up to 400 kg
Off
T-ONE10B For gates from 600 to 1000 kg
Off
T-ONE8BR (24v)
Off
MASTER-R (24V Opening speed = Closing speed)
On
MASTER18QR
On
MASTER-R (24V)
On
T-ONE8BR (24V Opening speed = Closing speed)
On
CANTILEVER TONE10B (heavy)
On
RESISTIVE SENSITIVE EDGE (terminal No. 10).
NC CONTACT SENSITIVE EDGE ( terminal No. 10).
Off
Note: if not used, keep the DIP in the OFF position.
20