Verify that a tight seal exists between the side wall and the
flange. If not, repeat above steps.
C: Installation of 12VDC Power and User
Control Panel (UCP)
1.
SET THE WATER HEATER POWER SWITCH TO THE
"OFF" POSITION and connect the power supply wires
(on rear of water heater – Red & Black wire). Red wire to a
12VDC circuit from the DC panel protected with an interior
power switch (not provided) and a 10 amp fuse. Connect
Black wire to a ground connection on the panel.
NOTE - The Red wire is positive (+) and the Black wire is
negative (-).
2. Determine location for the User Control Panel (UCP –
Figure 5) inside the RV. Drill a ¾" hole and then run 2 – 18
gauge wires from the rear of water heater to the ¾" hole
(maximum wire length is 16' or 5M). Connect the 2 wires to
the User Control Panel 2 wires and to the 2 wires on rear of
water heater (UCP wires are Blue or Blue/Green). Note –
UCP wires can be connected to either color/lead wire.
CAUTION - Do not connect UCP wires to the power wires
(BLACK or RED) on rear of water heater.
INSTALLATION NOTE – The micro processor is always on. It
CCD-0005833 Rev: 04-14-22
°C / °F
draws approximately .20AMPs so it is advisable to turn OFF
the 12V power when in storage or dry camping. This can be
accomplished by installing or utilizing an interior power switch
(not provided) or turning the Water Heater circuit OFF.
DO NOT use matches, candles or other sources of ignition
when checking for gas leaks.

D: Functional Tests

1.
Verify the power switch on water heater is in the "OFF"
position (located inside water heater compartment) or the
interior Water Heater Power Switch (if installed).
2. Turn on the water supply to the unit.
3. Open and then close the HOT & COLD water faucets in the
vehicle to fill the pipes with water. If needed, purge air out of
all water lines including washers, toilet and outside faucets.
Close the faucets when the water is flowing smoothly and
verify that there are no leaks at the connections and within
the water heater.
4. Confirm that there is a "steady" water flow (not pulsating). If
pulsating have the water pump settings adjusted.
5. Turn on the gas supply and check all gas connections
for leaks including exterior gas connection and gas
connection to the gas valve inside the Water Heater
compartment.
6. Turn the power switch to the "ON" position and verify the
UCP is illuminated (push RED power button on the UCP to
illuminate). It will show the Hot Water temperature setting.
7.
The recommended and factory setting is 115°F or 46°C.
8. Open a Hot water faucet and verify that the unit ignites and
supplies hot water at the faucet.
9. The UCP display will show the following icons: fan, flame
and water temperature. See page
identifications.
10. WHILE UNIT IS RUNNING, verify that there are no leaks
at the external gas connection and in proximity of the Gas
Control within the unit.

E: Door Installation

It is necessary to use only an applicable F2GWH Furrion
Water Heater Door Kit with a Furrion F2GWH Water Heater.
Use of any other brand of water heater door will affect the
operation and performance of the Furrion Water Heater and
may cause a hazardous condition.
The door of the F2GWH water heater is hinged on the left side
of the mounting flange and swings open from the right. The
latch must secure the door closed at all time during operation.
- 5 -