StormPro
Battery Back-Up Power Supply
After taking the above precautions, lower the 12V
battery into the enclosure with the terminals facing
the front of the Unit where the indicator lights
and battery cables are located. At this time check
the polarity of your marine battery. Facing the
front of the Unit, the left battery terminal should be
positive, and the right negative. If this is not the
case do not continue until the proper battery can
be obtained. (Do not try to correct this problem
in any other way than by using the proper battery).
Now that the battery has been installed with the
terminals nearest to the red and black wires.
PLUG THE UNIT INTO A 120V OUTLET BEFORE
CONNECTING THE BATTERY LEADS. With
the Unit plugged into the 120v outlet connect the
battery leads to the marine battery making sure the
red wire is connected to the positive
terminal and black wire is connected to the negative
terminal. Make sure all battery connections are
properly tightened to 75 inch pounds. Then place
the battery box cover back
on the Unit and strap it down so that children cannot
tamper with the Unit. At this time you
may plug the high efficiency pump supplied with
the System into the back of the piggyback plug on
the Unit.
DO NOT PLUG ANYTHING OTHER PUMP
THAN THE STORMPRO MODEL#BA-33V PUMP
SUPPLIED WITH THE SYSTEM INTO THE
POWER SUPPLY. DOING SO WILL VOID THE
WARRANTY!
FUNCTIONS AND LIGHTS:
The GREEN Power On indicator light should remain
on as long as standard line power is available.
1. Flashing GREEN light is normal and indicates
that the battery is fully charged.
•
The green should remain flashing indicating
that the system is ready for operation.
2. Continuously lit GREEN light indicates that the
battery is charging.
•
The battery is charging due to normal
discharge.
•
The system has run off of the battery and the
Register your product at
www.sumpro.com
OPERATION MANUAL
Dated: 12/12/08
Supersedes: None
Document No.: SP-OM
power supply is recharging the battery to its
optimum level.
The RED Inverter/Battery On indicator light should
only appear when the power is out or there is a
problem with the system.
1. Single flashing RED light indicates a low
battery.
•
The battery most likely needs to be replaced.
Contact your installer or Metropolitan Industries
for a compatible replacement battery.
2. Double Flashing RED light indicates the unit
has overloaded.
•
The pump plugged into the power supply
exceeds the power supply's rating of 5 amps.
Only use a Stormpro 1/3HP pump Model # BA-
33V with the StormPro power supply.
•
The pump is malfunctioning and is running at
a higher amperage than normal.
your pump will need to be repaired or replaced.
Contact your installer or Metropolitan Industries
for further assistance.
Metropolitan Industries, Inc.
www.metropolitanind.com
Page 2 of 11
Most likely