ATTENTION: Before starting the electrical connections, check the voltage (230V or 400V) selector switch to be
set correctly.
!
In cases a motor with mechanical brake is used or a control board ELPRO 14 is replaced, the DIP-switch A
No.12 has to be in OFF.
SAFETY EDGE
LIMIT SWITCH
in CLOSING
M2
Power supply
24V - 50mA max.
_
+
30 31
32 33 34
L30 L31
L33 L34
26
27
JB
RUN TIME
28
0s - 120s
1 2
CARD
CONNECTOR FOR
TRAFFIC LIGHTS
DIP-SWITCH - A
(Item 7282L)
ON
OFF
1 2 3 4 5 6 7 8 9 10 11 12
PLUG-IN
RADIO
CARD
CONNECTOR
E 37
L
L1
L4 L5 L6 L7 L8
L0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
NC
pedestrian
LIMIT SWITCH
General description: the electronic control box ELPRO 37 DS has been developed to provide a reliable unit to control double-leaf sliding gate automatic
systems with or without electronic brake and limit switches. Single-phase 230V 50/60Hz or Three-phase 400V 50/60Hz ELPRO 37 DS complies with the Low
Voltage Norms 2006/95 CE and Electro-magnetic Compatibility 2004/108/CE. Installation is recommended by qualified technical installation agents in
compliance with the existing regulations. The manufacturer is not liable for any incorrect use of this appliance; and also reserves the right to change and
update it without previous notice.
IMPORTANT FOR THE INSTALLATION AND THE CORRECT FUNCTIONING:
- The control box must be installed in a dry and sheltered place; suitable holes are provided with the FADINI universal box for fitting purpose and in
case any commercial box is used, this must be adequate to the job.
- Make sure that power supply to the control board be
- Make sure that power supply to the electric motor be
- For distances longer than 50 metres increase the section of the wires.
- Fit the mains to the control box with a high sensitivity, 0.03A, differential, magnetic-thermal circuit breaker.
- Cables with 1.5mm² section wires are to be used for the power supply, electric motor and flasher for distances up to 50 m.
- Cables with 1mm² section wires are to be used for the limit switches, photocells, push buttons and accessories.
- If no photocells are used link out terminals 1 and 2.
- If no stop button is used link out terminals 3 and 6.
- Open/Close motor run time trimmer must be always superior to the time actually required for the gate travel.
N.W.: For applications such as light switching, CCTV, etc. use solid state relays to prevent the microprocessor from being affected.
Diagnostic LEDs:
L ON
= Board on 230V or 400 V voltage and F1, F2, F3, F4, F5, F6 fuses all right
L0 ON = Pedestrian mode, it switches on by any pedestrian pulse
L1 ON = Pair photocells in Closing not obstructed
L4 OFF = Open, it switches on by any open pulse
L5 OFF = Close, it switches on by any close pulse
L6 ON = Stop, it switches off by any stop pulse
L7 OFF = Radio, it switches on by any pulse from the transmitter/radio contact
L8 ON = It switches off when Fc.A. (limit switch Opening = L-sw.O) is engaged, M1
L10 ON = It switches off when Fc.C. (limit switch Closing = L-sw.C) is engaged, M1
L30 ON = It switches off when Fc.A. (limit switch Opening = L-sw.O) is engaged, M2
L31 ON = It switches off when Fc.C. (limit switch Closing = L-sw.C) is engaged, M2
L33 ON = Safety edge protecting closing not obstructed
L34 ON = Safety edge or photocell protecting opening not obstructed
IN CASE OF FAILURE PLEASE MAKE SURE THAT:
- Power supply to the electronic control board is 230V ±10% or 400V ±10%
- Power supply to the electric motor is 230V ±10% or 400V ±10%
- All of the fuses is all right
- The photocell contacts are closed
- No voltage drop has occurred from the Elpro board to the electric motor
- All of the NC contacts of the control board are all right.
- The limit switches are properly connected and work correctly
SINGLE – THREE PHASE ELECTRONIC CONTROL BOARD WITH ELECTRONIC BRAKE FOR
DOUBLE-LEAF SLIDING GATE AUTOMATIC SYSTEMS WITH OR WITHOUT LIMIT SWITCHES
SAFETY EDGE
in OPENING
PEDESTRIAN
DWELL TIME
T.FUN
1s - 45s
1s - 220s
DIP-SWITCH - B
F6=2A protection
ON
24V
OFF
1 2 3 4
24V AC output
for photocell TX
UNL
enabling DSA control
UNL
SETUP
L10
JA
EDGE
TYPE
1 2
16
M1
230V ±10% or 400V ±10%.
230V ±10% or 400V ±10%.
230V
400V
F4=2A transformer and
electronic brake
protection
17
18
19 20
21
22
M1
CONNECTION OF A SECOND
ELECTRIC MOTOR
ATTENTION: Remove the
connector of single phase
!
power supply
common
23
NOTE:
The green LEDs must
always be on.
meccanica
FADINI
M2
Resistive contact
8,2 k
or NC
Ω
page 9