Specifications - Wolf EC2450TE/S Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Specifications

Installation Requirements
The Coffee System can be installed in a standard or flush
inset application. The sides of the cabinet opening must
be adequate to support installation of the mounting slides.
Refer to the illustration below.
If a Coffee System is installed above a Cup Warming
Drawer, specify one opening for both units.
Finish the edges of the opening.
For standard installations, the face trim overlaps stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 1/8"
required on all sides. Each corner of the opening must be
exactly 90° to maintain consistent reveals.
INSTALLATION REQUIREMENTS
Minimum Base Support
TRIM OVERLAP
Top
Bottom
Sides
3
/
"
4
(19)
TYPICAL
14"
3"
( 76 )
(356)
Slide support
reveal is
(3)
100 lb
(45 kg)
24" MODEL
30" MODEL
3/16"
3/16"
(5)
(5)
0"
0"
(0)
(0)
11/16"
3 7/8"
(18)
(98)
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on
pages 6–7. A separate circuit servicing only this appliance
is required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
Power Cord
RATING PLATE
Rating plate location
grounded, 120 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
6'
(1.8 m)
wolfappliance.com | 5