Your EuroCave wine cabinet is an appliance with tried and tested performance.
Maintenance operations to be carried out every 3 months
•
Remove the 2 screws from the grille with a no. 2 hexagonal spanner (provided int the accessories bag).
•
Remove the grille, take out the filter and place under running water.
•
Leave to dry and refit the assembly.
Maintenance operations to be carried out approximately once a year
•
Unplug and unload the appliance.
•
Clean the condenser at the back of the appliance, removing dust with a vacuum cleaner.
•
Clean the inside of the compartments with water and a gentle cleaning product.
•
Rinse thoroughly.
•
Replace the active carbon filter housed in the upper ventilation hole in your cabinet (see chapter 5).
Manually remove the carbon filter. It is available from your usual dealer. It must be replaced using a
manufacturer guaranteed part.
•
Check that the door seals are in good condition.
Possible incidents
The icon
displays
The icon
is still displayed even
though I have performed the corrective
action above
The icon
displays
The icon
flashes
The apparatus cannot lower the humidity
to the desired level.
The icon
displays
The icon
displays
If your appliance appears to be functioning abnormally, contact your EuroCave dealer.
7 - E
Causes
Corrective action
The temperature
Check the door is closed properly.
has not dropped
Check the condition of the door hinge.
below the limit of
If you have placed a large number of bottles in your cabinet in the past few hours,
±4°C / 39°F
wait a short while then check the temperature again..
If the alarm persists, contact your EuroCave dealer.
Operating faults
Disconnect the cabinet and contact your EuroCave dealer.
Open door alarm Ensure the door is closed properly.
The relative
Add a glass of water on the humidity cassette (see chapter 7, § IV).
•
humidity rate
In order to obtain the time interval for adding water, count the number of days
•
falls below 65 %
between the 1st day when water was added and the day when the pictogram was
for more than 72
displayed.
hours
After a few hours the icon will go out.
•
Empty the cabinet, remove the humidity cassette and clean the tank.
Remove the tube positioned on the bottom of the tank. The humidity will be
•
directly removed from the apparatus.
Adjust the level of humidity to 75 % but do not install the pozzolana cassettes
•
or replace them with new ones.
Call the EuroCave dealer is the problem persists despite these different actions.
Carbon filter
Replace the carbon filter (see chapter 5).
alarm
Temperature
Contact your EuroCave dealer.
sensor defect
alarm
VERYDAY MAINTENANCE
2
Your appliance is equipped with a frost prevention
device to protect you in the event of a cold circuit
failure.
8 - O
PERATING FAULTS
1
37
EN