Télécharger Imprimer la page

elobau 471 M41 H31 Traduction De La Notice D'utilisation D'origine page 24

Masquer les pouces Voir aussi pour 471 M41 H31:

Publicité

Les langues disponibles

Les langues disponibles

-
Ensure that the control unit is only used for protection against dangers.
-
Ensure that all safety requirements applying for the machine in question are
observed.
-
Ensure that all European guidelines and national laws/guidelines applying
are observed.
-
Ensure that the switches are always switched over in a deenergized state.
3
Function
The control unit consists of two independent units.
Unit
Components
1
-
Sensor inputs S1 and S2
-
Input external contactor 1 and 2
-
Safety outputs SA1 and SA2
-
Control outputs A1 and A2
2
-
Sensor inputs S3 and S4
-
Input external contactor 3 and 4
-
Safety outputs SA3 and SA4
-
Control outputs A3 and A4
Unit
Can be used as
1
-
Control unit
-
EMERGENCY OFF relay
-
2-hand control
2
-
Control unit
-
EMERGENCY OFF relay
Each unit is equipped with 2 sensor inputs with 2 contact makers each. Each sen-
sor input drives one control output.
NOTE
Each control output allows controlling one SPS.
The safety outputs of this unit switch on when both sensor inputs of a unit are re-
activated.
900565 / 04.04.2016
All manuals and user guides at all-guides.com
with cross short detection
with delayed switch-off of control outputs
GB
23

Publicité

loading