R62 SECUTEC Parameter
D = Wert wird beim Laden der Defaultparameter nicht zurückgestellt
└►
Light
└►
PPowerSave
└►
TPowerSave
└►
TOffDelay
└►
Voice Output
└►
PEnableMsg1
└►
PEnableMsg2
└►
PEnableMsg3
└►
PEnableMsg4
└►
PEnableMsg5
└►
PEnableMsg6
└►
PEnableMsg7
└►
PEnableMsg8
└►
PEnableMsg9
└►
PEnableMsg10
└►
PEnableMsg11
└►
PEnableMsg12
└►
PEnableMsg13
└►
PEnableMsg14
└►
PEnableMsg15
└►
TBetweenMsg
└►
Inputs
└►
AUX01_IN
└►
AUX02_IN
└►
AUX11_IN
└►
AUX12_IN
└►
AUX21_IN
└►
AUX22_IN
└►
Outputs
└►
AUX11_OUT
└►
AUX12_OUT
└►
AUX21_OUT
└►
AUX22_OUT
└►
AUX23_OUT
BMS
└►
BMS Invert Logic
└►
BMS1
└►
PLogicRL1
└►
PLogicRL2
└►
PLogicRL3
└►
PLogicRL4
└►
PLogicRL5
└►
PLogicRL6
└►
PLogicRL7
└►
PLockedClosedRL7
└►
PLogicRL8
└►
PLockedClosedRL8
OFF
ON
30
(min.)
20
(ds)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
3
(min.)
0 ... 3
0
0 ... 3
0
0 ... 3
0
0 ... 3
0
0 ... 3
0
0 ... 3
0
0 ... 2
0
0 ... 2
0
0 ... 2
0
0 ... 2
0
0 ... 2
0
norm
inv
norm
inv
norm
inv
norm
inv
norm
inv
norm
inv
norm
inv
lock
clos
norm
inv
lock
clos
power safe mode activated (ON) or deactivated (OFF)
delay time before light is switched off when door is not used
delay time to switch off the lights (when changing the operating modes)
enable / disable the voice message 1
enable / disable the voice message 2
enable / disable the voice message 3
enable / disable the voice message 4
enable / disable the voice message 5
enable / disable the voice message 6
enable / disable the voice message 7
enable / disable the voice message 8
enable / disable the voice message 9
enable / disable the voice message 10
enable / disable the voice message 11
enable / disable the voice message 12
enable / disable the voice message 13
enable / disable the voice message 14
enable / disable the voice message 15
delay time to repeat the voice message when the same function/message is still
triggered
0 = no function;
1 = maintenance mode;
2 = cleaning mode from secure side;
3 = cleaning mode from public side;
4 = tailgating sensor off (permanently deactivated)
0 = no function;
1 = person passed way in;
2 = person passed way out;
output logic of the relay contact
norm: enabled when message is active; inv: enabled when message is inactive
output logic of the relay contact
norm: enabled when message is active; inv: enabled when message is inactive
output logic of the relay contact
norm: enabled when message is active; inv: enabled when message is inactive
output logic of the relay contact
norm: enabled when message is active; inv: enabled when message is inactive
output logic of the relay contact
norm: enabled when message is active; inv: enabled when message is inactive
output logic of the relay contact
norm: enabled when message is active; inv: enabled when message is inactive
output logic of the relay contact
norm: enabled when message is active; inv: enabled when message is inactive
output function of the relay contact
lock: status message door is locked; clos: status message door is closed
output logic of the relay contact
norm: enabled when message is active; inv: enabled when message is inactive
output function of the relay contact
lock: status message door is locked; clos: status message door is closed
≥ V0.13.0